Classifying Functional Locations 
Prerequisites
A master record must exist for the functional location
The required classes and characteristics must exist
For more information, see
Creating and Changing Characteristics and Classes.
Procedure
Select the master record in the screen Technical Objects by choosing FunctLocation
®
Change.
You can call up the classification function from the Location Data and the PM Data screens.
Choose Goto
®
Classification.

If several class types have been maintained in Customizing for Cross-Application Components under Classification System
®
Classes
®
Object types
®
Class types, the system displays a dialog box in which you can select the required class type.The screen Change Functional Location: Classification is displayed.
Enter the classes to which you want to assign the functional location in the column Class.
Select the class that is to be the standard class for the functional location in the field StdClass.
To specify value entries for the class, position your cursor on the class you require and choose Edit
®
Values.
The screen Change Functional Location: Char.Val.Assigmt. is displayed.
Enter the values for the specified characteristics.
Choose Goto
®
Back to return to the screen Change Functional Location: Classification.When you have entered the values for all the classes you require, you can return to the master data screen from which you called up the classification function by using the menu bar sequence Goto
®
Back.
Save the changes to master record.