Two objects used in assembly processing in the Project System can be configured: the standard network and the material. You can use both a configurable material and a configurable standard network in one assembly order.
To use configuration, you assign a configuration profile to the configurable object. This profile contains details about the class to be used.
For information about variant configuration, see the SAP Library for
Variant Configuration
in
Logistics - General
(LO-VC)
.
If you want to use configuration, you have to have previously created the characteristics that you want to use in the variant class. For more information, refer to Maintaining Characteristics and Classes for Config .
If both the material and the standard network are configurable, they should be assigned to the same class. If the standard network has not been assigned to a class (it does not have a configuration profile), then the configuration from the material is used. This is also the case, if the class for the standard network is part of the class for the material. Otherwise the characteristic values are assigned separately when the network is created.
To use configuration with a material, you have to have set the
Material is configurable
indicator on the
Basic data
view (in the standard system) of the material master.
Choose
On the initial screen enter the name of the new class and the class type. In the standard system the class type for configuration is 300 throughout the system.
Note
The class system is also used for other purposes in SAP. In such cases other class types are used. For instance, class types 013 and 014 are used for summarization in the Project System.
Choose
Enter
and on the next screen enter a description of the class.
Choose
.Enter the characteristics that you want to use in this class.
Save and exit.
The procedure for creating a configuration profile for standard networks and materials is basically the same.
Choose
and then .Choose
and then In both cases the
Select Configurable Object
dialog box appears. Make sure that the correct object has been selected, change if necessary.
Note
If instead of the dialog box the initial screen for the incorrect object appears (for example, if you want to create a configuration profile for a material and the initial screen for standard networks appears), choose
dialog box appears.Continue for both objects as follows:
Choose
Continue
.
Enter the number of the material or the standard network on the initial screen. Choose
Enter
.
On the next screen enter a name for the profile and the class type 300. You can also restrict the organizational areas in which the profile is valid by making an entry in
the Org. areas
field.
Choose
.Enter the class that you defined previously.
Save your entries.
For more information on configuration in the Project System, see Configuration .