BC - Generate Table Maintenance Dialog
Generate Table Maintenance Dialog
Creating Maintenance Dialogs
Maintenance View
Initial Screen
Creating Maintenance Dialogs
Delete Maintenance Dialog
Maintain Authorization Groups
Maintain Authorization Group Assignments
Maintain Function Groups
Maintenance View Variants
Creating Maintenance View Variants
Environment Menu
Maintain Events
Maintaining Parameter Transaction Codes
Utilities Menu
Changing a Maintenance Dialog
Maintaining the Maintenance Dialog
Modifying Maintenance Object
Making Dictionary Changes
Maintenance View Variants for Modified Dialogs
Creating Tabs for Maintenance Dialogs
Time-Dependent Table/View
Generate Time-Dependence
Technical Background
Adjustability Criteria from Release 4.5B
Extended Table Maintenance Events
Event 01: Before Saving the Data in the Database
Global Variable <STATUS>-UPD_FLAG
Constants for field symbols <ACTION>, <ACTION_TEXT>, <XACT>, and <XACT_TEXT>
Event 02: After Saving the Data in the Database
Event 03: Before Deleting the Display Data
Event 04: After Deleting the Display Data
Event 05: When Creating a New Entry
Event 06: After the 'Get Original' Function
Event 07: Before Correcting the Contents of a Selected Field
Field Symbols for the Work Area Table/View
Event 08: After Correcting the Contents of a Selected Field
Event 09: After 'Get Original' for One Entry
Work Areas
Event 10: After Creating the Change Req. Hdr Entries (E071)
Additional Transport Information
Event 11: After Changing a Key Entry in the Change Req. (E071K)
Transport Event Variable (10, 11, 12)
Event 12: After Changing a Key Entry in the Change Req. (E071K)
Event 13: End Processing
Event 14: After Locking/Unlocking in the Main Function Module
Event 15: Before Retrieving Deleted Entries
Event 16: After Retrieving Deleted Entries
Event 17: Before Printing Entries
Additional Print Information
Event 18: After the Data Change Check
Event 19: After Init. Global Variables, Field Symbols, and So On
Internal Table EXCL_CUA_FUNCT
Title Bar
Event 20: After Input in Date Subscreen (Time-Dep. Tables/Views)
Event 21: Fill Hidden Fields
Event 22: Go to Long Text Maintenance for Other Languages
Event 23: Before the Address Maintenance Screen Call
Function Module ADDR_DIALOG_PREPARE
Function Group SAPLSZA1
Field Selection Control Templates (Long Text)
Event 25: When Starting the Maintenance Dialog
Event 26: Before Displayed Data is Output in a List
Event 27: After Filling a GUID Field
Possible Changes to GUID Fields in the View Maintenance
Event AA: Instead of the Standard Data Read Routine
Event AB: Instead of the Standard Database Changes Routine
Event AC: Instead of the Standard 'Cancel Changes' Routine
Event AD: Instead of the Standard RO Field Read Routine
Event AE: Instead of the Standard Positioning Code
Event AF: Instead of Reading Texts in Other Languages
Internal Table <VIM_READ_LANGUS>
Data Transfer Table SEL_LANGUS
Event AG: Instead of 'Get original' for Texts in Other Languages
Event AH: Instead of Database Changes for Texts in Other Langs
Event ST: GUI Menu Main Program Name
Structure STATUS
Information Fields for the Functions
Standard Interface Status
Mark Additional Information
Detail Screen Selection Notes
Overview Screen Selection Notes
Variable IGNORED_ENTRIES_EXIST
Internal Table EXTRACT
Internal Table EXTRACT Work Area Field Symbols
Field Symbol <XMARK>
Constants for the Field Symbols <MARK> and <XMARK>
Field Symbols <XACT> and <XACT_TEXT>
Internal Table TOTAL
Internal Table TOTAL Work Area Field Symbols
Field Symbol <MARK>
Field Symbols <ACTION> and <ACTION_TEXT>
Internal Transport System Link Table
Internal Table <VIM_TEXTTAB>
Global Variable NEXTLINE
Unicode Conversion Information
Converting Generated Table Maintenance Dialogs to Unicode
Regenerate Maintenance Dialog
Report RSVIMT_UC_VIEW_MAINT_GEN
Get Functional Enhancements
Converting the Data Containers TOTAL and EXTRACT
Global Parameters and Events for Maintenance Dialogs
View Maintenance Interfaces
Transport Connection with CORR_KEYTAB (Structure E071K)
Creating View Clusters
Define a View Cluster
Header
Object Structure
Field Dependencies
Activating View Clusters
The Error Log
Modify a View Cluster Maintenance Dialog
View Clusters: Technical Background
Modify Navigation Subscreen Title and Position Text
Deactivating Menu Functions
Call the Ciew Cluster Maintenance Dialog
Maintain Events
Adjustability Criteria from Release 4.5B
View Cluster Maintenance Variants
Create View Cluster Maintenance Variant
View Cluster Maintenance Events
Technical Background for View Cluster Events
Global Data of View Cluster Maintenance
Global Variables
Maintenance and Data Tables for Each Subobject
Internal Table "EXTRACT" (View Cluster)
Internal Table "TOTAL" (View Cluster)
Processing and Selection Flags
Selection Tables DBA_SELLIST and DPL_SELLIST
Unicode Conversion of View Clusters with Global Parameters
Unicode Conversion of View Clusters with Events
Event 01/VC: After Initializing Global Variables, Field Symbols
Event 02/VC: After Getting the Database Access Select Conditions
Event 03/VC: Before Calling View Maint Module for a Subdialog
Event 04/VC: Before Saving the Data in the Database
Event 05/VC: After Saving the Data in the Database
Event 06/VC: After Locking/Unlocking in the Main Function Module
Event 07/VC After Leaving the View Maintenance Module for Subdialogs
Event 08/VC: At the End of View Cluster Maintenance
Event 09/VC: When Getting Navigation Selection Conditions
Event 10/VC: Before Getting Navigation Selection Conditions
Event 11/VC: When Determining the Dep. Entr. for Hier. Operations
Event 12/VC: When Getting Higher-Level Entries for Hierarch. Ops
Event EQ/VC: To Create User Lock Logic
Event GR/VC: To Determine User Database Access Select Conditions
Event RE/VC: Define a Read Routine
Event SV/VC: Define a Data Save Routine
Event CK/VC: To Check New/Changed Entries