Show TOC

 Clock In/Clock Out Password (New)

Technical Data

Product Version

SAP Point-of-Sale (POS) 2.3

Area

IS-R-TGM

Country Relevance

Valid for all countries

 

This release of SAP POS has been enhanced to provide the ability to disable prompting for the entry of a password for the Clock In/ Clock Out functions when the employee number is either scanned or swiped. If the employee number is manually entered then the regular process of prompting for a password is still required.

Effects on System Administration

The method used for clocking in and out will be printed in the TLOG and Journal when this feature is enabled.

Effects on Configuration

If you choose to enable this feature, the following Configurator options must be selected:

  • Select Register Parameters from the Terminal tab of the Configurator and then select the Employee/Supervisor tab. From this tab in the Register Parameters Maintenance window

    • Select the Disable Clock In Out Password: checkbox.

    • Select the Strip Leading Zeros from Scanned Employee Numbers for Clock In/Out: checkbox. This will strip the leading zeros and remove the check digit of the employee number obtained from the scanned data.

  • Select Register Parameters from the Terminal tab of the Configurator and then select the Min/Max Digits tab. From this tab in the Register Parameters Maintenance window, set the appropriate minimum and maximum digits for the Employee #:.

More Information

For more information, see the SAP Service Marketplace and the SAP Library under Start of the navigation path http://help.sap.comInformation published on SAP site Next navigation step SAP for Industries Next navigation step SAP for Retail Next navigation step SAP Point-of-Sale End of the navigation path.