Syntax documentationCommand Options for BRCONNECT Locate this document in the navigation structure

This section describes the command options for the BRCONNECT tool.

If you use BRCONNECT with command options, these override the corresponding values in the initialization profile init<DBSID>.sap. To use the options, you can specify either the letter indicated or the complete word.

This is the schematic command syntax:

Syntax Syntax

  1. brconnect [<command_options>] -f|-function <function> [<function_options>]
End of the code.

This is the full command syntax:

Syntax Syntax

  1. brconnect
  2. [-c|-confirm [|force]]
  3. [-h|-help [<function>]|[version]]
  4. [-l|-language E|D]
  5. [-o|-output detail|process|summary|[,]time]
  6. [-p|-profile <profile>]
  7. [-q|-query [check|nolog]]
  8. [-s|-sapsid <sid>|<sid_list>]
  9. [-u|-user [<user>[/<password>]]]
  10. [-V|-VERSION [ALL]
  11. -f|-function <function> [<function_options>]
End of the code.

Example Example

brconnect -output detail -function check -default

End of the example.

See also:

-c|-confirm

-h|-help

-l|-language

-o|-output

-p|-profile

-q|-query

-u|-user

-V|-VERSION

-f|-function