This functionality enables you to navigate quickly between two versions of the same
development object in two different projects.
Prerequisites
The same development object has to exist in the system in which you want to open
it.
The shortcuts are only provided in SAP NetWeaver 7.4 SP09 and
higher.
Procedure
- You can initiate the functionalities from the following positions:
- Select the relevant node in the Project
Explorer.
- Open the development object in the ABAP source code
editor.
- Open the context menu and choose Open in Project.
Tip Alternatively, you can use the Ctrl Alt P
shortcut to open the submenu with the project list directly.
- Select the project in which you want to open the development object.
Note If the project does not exist, you can create a new one by selecting
New Project...
Note Alternatively, you can also use the Alt Shift P shortcut.
ABAP Development Tools (ADT) then automatically opens the development object
in the project you opened previously. Thus, you can easily toggle between
both projects.
Results
In the editor, the development object of the other system is opened.