The parameters described below are used to configure the gateway to ensure secure connections.
Refer also to Security Settings in the Gateway.
Your system must be configured for using the SNC interface.
gw/acl_file
This parameter specifies the name of an access control list (ACL) file. With an ACL you can configure who is permitted to connect to the gateway.
The same ACL file is used for the standard port and for the SNC port of the gateway.
If the specified ACL file does not exist or is erroneous, the gateway immediately closes.
If the parameter is not set, access control is not valid.
Default Setting |
Empty (no ACL file is used) |
Dynamic |
No |
For more information, see: Configuring Network-Based Access Control Lists (ACL)
gw/acl_mode
The parameter defines the behavior of the gateway, if no ACL file ( gw/sec_info or gw/reg_info) exists.
The following values are permitted:
0 : There is no restriction with starting external servers or registering servers.
This setting should not be used in production operation.
1 : External and registered servers are only permitted within the system (application servers of the same system). All other servers are rejected or have to be maintained in the respective files.
Default Setting |
1 |
Dynamic |
Yes |
gw/logging
With this parameter you can configure gateway logging. You can specify whether the gateway writes its actions to a log file, which types of actions are logged, and how the file is renamed. You have the options to define a maximum size for the file, and to specify whether old files are overwritten.
If the gateway is running in an AS ABAP instance, we recommend you make settings for gateway logging in the gateway monitor (transaction SMGW). If you want to make permanent logging settings so that it works again after the instance has been restarted, you have to set this parameter in the profile.
You must set the parameter as follows:
gw/logging = LOGFILE=<name> ACTION=[TERSMPXVCO]
[MAXSIZEKB=n] [SWITCHTF=t] [FILEWRAP=on]
The meaning of the individual elements is as follows:
LOGFILE: File name of the log file
ACTION: The character sequence (subset from TERSMPXVCO) specifies the actions to log.
MAXSIZEKB (optional): Maximum file size. As soon as the file exceeds this size, a new file is opened, whereby the new file name can change if special characters are used. This is a the case unless a condition was specified for SWITCHTF that applies first.
SWITCHTF (optional): Opens a new file after a specific time period, unless a condition was specified for MAXSIZEKB that applies first.
The following values can be specified:
year: After one year a new file is opened
month: After one month
week: After one week
day: After one day
hour: After one hour
FILEWRAP (optional): Reuse file. This parameter can only have value ON. If this value is set, no new file is written, but the one already open is reset and rewritten to. The values for parameter LOGFILE are only used the first time the file is opened.
gw/monitor
This parameter specifies how the Gateway handles monitor commands.
The following values are possible:
0: No monitor commands are accepted
1: Only commands from the local Gateway monitor are accepted
2: Commands from local Gateway monitors and external Gateway monitors are accepted.
Default Setting |
1 |
Dynamic |
Yes (Though only in the direction of more security, that is, from 1 to 2, and not from 2 to 1) |
Dynamic yes
gw/sec_info
File with the security information.
Any unauthorized starting of external programs can be prevented by maintaining the file secinfo in the data directory of the gateway instance.
Default Setting |
<Data Directory>/secinfo |
Dynamic |
No (Values cannot be changed dynamically, but you can completely reload the file when the gateway is running) |
For more information, see: Making Security Settings for External Programs
gw/reg_info
File with the security information for registered programs.
Unauthorized registration of programs can be prevented by maintaining the file reginfo in the data directory of the gateway instance.
If the file exists, the system searches for valid registration entries in this list. If there are none, the system searches, as up to now too, in the gw/sec_info file.
Default Setting |
<Data directory>/reg info |
Dynamic |
No (Values cannot be changed dynamically, but you can completely reload the file when the system is running) |
For more information, see: Making Security Settings for External Programs
SNC Parameters
There are a number of additional parameters that control the behavior of the Gateway in conjunction with SNC (Secure Network Communication).
Parameter |
Meaning |
Default Value |
Dynamic |
|---|---|---|---|
snc/enable |
This parameter specifies whether the gateway accepts connections that protect the data via SNC. |
0 |
No |
snc/permit_insecure_comm |
This parameter specifies whether the gateway accepts connections without SNC. |
0 |
No |
snc/permit_insecure_start |
This parameter specifies whether the gateway may establish connections with programs that communicate without SNC. |
0 |
No |
snc/permit_common_name |
This parameter specifies whether the gateway can use a default SNC name specified by the parameter snc/identity/as, if an SNC name for the connection cannot be read from secinfo. |
0 |
No |
snc/gssapi_lib |
Path for the shared library of the security system in use. |
"" |
No |
snc/identity/as |
Identity of the gateway application server |
"" |
No |