 Setting Up a Central Data CacheLocate this document in the navigation structure

Use

You can use a central data cache to improve the performance of the Alert Monitor when creating the alert monitoring trees. Data for the various nodes is stored on the local application server in this cache, so that expensive RFC calls to the monitored systems are only necessary when the defined life span of the monitoring tree elements in the cache has expired. Depending on the attribute, this is between two minutes (performance attributes) and twenty minutes (text attribute).

In the ideal case, absolutely no RFC calls are required from the central monitoring system, especially if the monitoring data is transferred from remote systems using agents that use push technology as of SAP Web Application Server 6.10. The agents then deliver their values once per minute directly to the central data cache, if they are registered on the server on which the cache is set up.

The basis of the central data cache is the technology of the Internet Server Cache (ISC). This is a cross-process cache in the main memory of an application server.

Note

The central data cache is in the ccmcache subdirectory of the $DIR_DATA subdirectory. You can display the size of the cache and the age of the entries using transaction AL11 (SAP Directories).

Procedure

Create Logon Group

As the central data cache only exists on one application server, you should ensure that you always call the Alert Monitor on this application server. We recommend that you create a logon group that consists of only one application server:

  1. Start transaction SMLG (CCMS: Maintain Logon Groups)
  2. Create a new logon group by choosing Create Assignment ().
  3. The Create Assignment screen appears. Enter an appropriate name for the group in the Logon Group field, and the name of the application server on which you want to set up the central data cache in the Instance field.
  4. Ensure that the Ext. RFC enabled indicator is activated on the Properties tab page.
  5. Save your entries.

Activating a Central Data Cache

You activate the central data cache using the profile parameter alert/cache/size_MB. This parameter is not set by default, meaning that the central data cache is deactivated.

  1. Start transaction RZ10 (Edit Profiles).
  2. Use the input help for the Profile field to select the instance profile of the application server for which you want to activate the central data cache.
  3. Ensure that Extended Maintenance is activated in the Edit Profile group box and choose Change ().
  4. The system displays a list with the profile parameters for this instance. Create the parameter alert/cache/size_MB if it is not in the list, and enter the size of the central data cache in megabytes.
    Note

    We recommend the following values as the size for the central data cache:

    Platform Recommended Size in MB

    32 Bit

    We recommend 4; if you are using a dedicated monitoring system with a small number of users, you can increase the value for the parameter to 10 to 20. Note, however, that the central data cache requires the Extended Global Memory (parameter em/Global_area_MB) when used in the main memory, which can be very scarce on 32 bit platforms due to the restricted address space. In this case, increase the value for the parameter em/Global_area_MB as described in SAP Note 329021.

    64 Bit

    10% of the parameter em/Global_area_MB, although from experience an increase of alert/cache/size_MB of over 40 does not provide any additional performance benefits. More information: SAP Note 146289.

  5. Save your entries.

Registering Agents with this Application Server

Ensure that the NetWeaver management agents are registered with exactly the logon group that you have intended for monitoring using the Alert Monitor. For information about registering the agents, see Registering SAP NetWeaver Components and Hosts in CEN.

Result

You have set up the central data cache on an application server. By setting up a logon group that consists of only this server, you ensure that the central data cache in the Alert Monitor is active if you always logon to this group to use the Alert Monitor.

Note

In your daily work with the Alert Monitor, you are normally only aware of the central data cache due to a better performance and the output Central data cache active at the top of the alert monitoring tree.

If new nodes are not correctly displayed (for example, after a new application server is started), you can delete all entries in the cache at any time. You do this using the Refresh and Invalidate Data Cache pushbutton ( ) (see Actions in the Alert Monitoring Tree ).