Show TOC

 Accessibility in Web Dynpro ABAP ApplicationsLocate this document in the navigation structure

To make a business application available to those users who are dependent on various levels of technical support due to disability, the Web Dynpro framework allows you to create accessible applications.

Note

For more information, see Accessibility .

Accessible User Interfaces

Tooltip

Tooltips for every UI element are essential to accessibility. Each UI element provides a tooltip.

A tooltip must be maintained for a UI element to support accessibility whenever:

The UI element does not have a heading

No label is assigned to the UI element

Elements with a text property have neither set nor bound it (with the exception of the caption, for which no tooltip is checked). For example, there is no text on a button or link.

A tooltip must be maintained for some more complex UI elements. Examples of these are the UI elements Tree or ProgressIndicator .

When you activate your component, a message is generated to tell you the contents of the tooltip property are missing (provided this property would have been necessary for the accessibility of the application). You can, however, define the value for the tooltip property dynamically. This option is not covered by the syntax check.

In addition, the tooltip property must always be set, for example, to provide more semantic information about the UI element.

AccessibilityDescription

Almost all UI elements additionally provide the property accessibilityDescription. This can be used to include a title, as an alternative, whenever the UI element should not or cannot carry a visible title (Header). In contrast to the case with the tooltip, which should contain a semantic description of the purpose of the UI element, only a short, title-like expression is entered in the accessibilityDescription

Note

More information on the individual UI elements is available under User Interface Elements .

You can find information about keyboard access in Web under Keyboard Access for Interface Elements in Web Dynpro .

Integration

When developing Web Dynpro ABAP applications, you can specify that you want to follow the accessibility rules. The procedures in pure WDA applications and in WDA applications integrated in the portal are different.

  • Pure WDA Applications

    The accessibility mode specification is integrated in the Web Dynpro runtime.

    1. Enter the accessibility mode in the URLsapurl:

      ...?sap-accessibility=X

      The accessibility mode is also specified in the System Logon .

    2. Enter the accessibility mode in your user parameters in the system.

      To do this, in transaction SU01 for your user name choose the tabstrip Parameters, insert the parameter ID ACCESSIBILITY_MODE with the value X, and save the entry.

    3. Enter the accessibility mode in the Parameters of your Web Dynpro application. To do this, on the tab page Parameters in your Web Dynpro application choose WDACCESSIBILITY with the value X and save your entries.
    4. Call the accessibility mode in the Web Dynpro runtime:

      You call it using method GET_IS_ACCESSIBLE in IF_WD_APPLICATION .

    This option sets an internal flag in the runtime, which can be used by applications to output additional information in the HTML output stream, so that screen reader programs can present the visual information on the screen more clearly.

    These parameters are not used after the logon.

    You can query this flag to check whether accessibility is a requirement. If the accessibility provided by Web Dynpro ABAP is not sufficient (for example, for displaying graphics), you can offer special help.

    Caution

    Note that setting this flag does not make any claims about an application's accessibility.

  • WDA applications integrated in the portal

    If your WDA application is integrated in the portal (see also Portal Integration ), you can specify and call the accessibility mode in the portal too.

    To do this, in your user profile in the portal, under General Information select option Activate Accessibility (Screen Reader Required) and save your entries. This specification is evaluated by Web Dynpro ABAP.

Checks During Design Time

During design time, accessibility checks are carried out automatically as part of the syntax checks.

By double-clicking on any component you can reach the properties and the indicator Accessibility Checks Active. If you deactivate this option, the development environment does not carry out any design time accessibility checks for the relevant component and its views. However, this is not possible if the component in transaction SACC is flagged as accessible.

In principle, no semantic checks can be carried out as the system cannot determine whether or not, for example, the content of a tooltip is useful within a given context. Instead, the system checks whether a specific property is set and filled. If this is not the case, the system checks whether any related properties are set.

Note

Note that the accessibility checks are not carried out for Web Dynpro ABAP test applications (temporary objects in the package $TMP). This also applies to applications in package SWDP_TEST.

Note also that these checks do not apply to dynamic UI element programming.

The following is a list of the checks that are carried out for the specified UI elements.

UI Element Checks

UI Element Type of Check

Button

ButtonChoice

LinkToAction

LinkToURL

ToggleButton

ToggleLink

ToolBarButton

ToolBarButtonChoice

ToolBarLinkToAction

ToolBarLinkToURL

ToolBarToggleButton

BreadCrumbStep

MultipleBreadCrumbStep

LegendItem

MultipleLegendItem

TextView

TreeNodeType

TreeItemType

MenuActionItem

If the text property was not set, the system checks for the tooltip property.

An error message is displayed if, for example, a button or link with an icon has neither the text nor the tooltip property.

CheckBox

RadioButton

FileDownload

TriStateCheckBox

If the properties text and label were not set, the system checks for the tooltip property.

An error message is displayed if, for example, a CheckBox has neither the text, label, nor tooltip property.

Group

Tray

If the caption property has not been set, the system checks for the accessibilityDescription property.

An error message is displayed if, for example, a group has neither the caption nor the accessibilityDescription property.

Image

If the label and isDecorative properties have not been set, the system checks for the tooltip property.

An error message is displayed if a tab-enabled image has an empty tooltip.

InputField

DropDownByIndex

DropDownByKey

ItemListBox

TextEdit

ToolBarDropDownByIndex

ToolBarDropDownByKey

ToolBarInputField

FileUpload

The system checks whether the label property has been specified.

If no label has been set, and no descriptive text has been specified for the appropriate bound context element in the ABAP Dictionary, the tooltip property is checked.

An error message is displayed if, for example, a TextEdit does not have a corresponding label or if a DropDownByKey does not have an assigned label and no description was entered in the ABAP Dictionary.

Table

If the caption property has not been set, the system checks for the accessibilityDescription property.

Furthermore, the system checks whether the aggregation header is set for columns or whether the aggregation header is visible.

The tooltip property is not checked.

An error message is displayed if a table has neither a caption nor an accessibilityDescription or if a column does not have a (visible) header.

CheckBoxGroup

RadioButtonGroupByIndex

RadioButtonGroupByKey

RoadMap

DateNavigator

PhaseIndicator

TabStrip

ToolBar

GeoMap

If the tooltip property has not been set, the system checks for the accessibilityDescription property.

An error message is displayed if, for example, a CheckBoxGroup has neither the tooltip nor the accessibilityDescription property.

TransparentContainer

If the layoutContainer property was not set, the system checks for the accessibilityDescription property.

An error message is displayed if a TransparentContainer has the property layoutContainer=false and does not have an accessibilityDescription.

Legend

The system checks whether the property legendId of the Legend element (Calendar, DateNavigator, Table) was set.

ProgressIndicator

ValueComparison

BusinessGraphics

GeoMap

IFrame

The system checks whether the tooltip property has been specified.

MenuActionItem

If the imageSource property has not been set, the system checks for the text property.

Phase

MultiplePhase

RoadMapStep

If the description property was not set, the system checks for the tooltip property.

Tab

The system checks whether the caption.text property has been set. If not, the system checks whether caption.tooltip is set.

Automatic Forwarding of Accessibility Flag

You can start another Web Dynpro application from a Web Dynpro ABAP application. This is done using an exit or suspend plug. To run the new application also in the accessibility mode, you do not have to transfer the accessibility flag itself in the URL for the application. Instead, if the URL is intended for another Web Dynpro ABAP application, the field can be transferred automatically (notation of the application is in curly brackets: {App}). The optional parameter IN_FORWARD_ACCESSIBILITY_FLAG in method CONSTRUCT_WD_URL of class CL_WD_UTILITIES is provided for this.

You can also append the field when the URL is generated.