This group of rules controls machine-related options as follows:
System Rule |
Description |
---|---|
CNC/DNC Server |
The name of the computerized numerical control (CNC) server to be used with the system LOCALHOST must be replaced with the name of the server. Default: LOCALHOST:port Can override at: site |
CNC/DNC Type |
None (default): Computerized numerical control (CNC) system is disabled. CNC: CNC system is enabled. Can override at: site, resource |
Default Resource |
The name of the default resource for all the operations in the Work Center PODs Default: DEFAULT Can override at: site |
Ignore Time Stamp in Client Messages |
true: Ignores time stamps from the client during validations for starts, completes, nonconformances, and parametric data. Use this rule in cases such as when the client clock does not match the rest of the system (the client clock is "out of synch"). false (default): Uses time stamps during validations Can override at: site, resource |