The following examples illustrate common settings for rollup.
The following examples assume operators work on SFC numbers one at a time. If operators work on multiple SFC numbers, the system divides SFC labor according to the setting of the Distribution of SFC Labor Time
field in Labor Rule Maintenance
.
For more information, see Labor Rule Maintenance.
Prerequisites:
On the Rollup Processing Rules
tab page in Labor Rule Maintenance
, you have set the Idle Factor
for
Labor Time
field to Labor
on to Labor off
.
You have created an indirect user LCC in Labor Charge Code (LCC) Maintenance
named IDLE_TIME
. This is the default user LCC for the operators in this example.
You have set up Labor on
to run on Start
and Labor off
to run on Complete
in POD Maintenance
.
The figure below illustrates Example 1
and is followed by an explanation:
Production operators clock in at the beginning of the shift, and the system starts charging their time against IDLE_TIME
. At the workstation, the operator works one SFC number at a time in the POD. The operator clocks out at the end of the shift without changing
his or her user LCC during the shift.
If you selected the Enable User Labor Summarization
checkbox on the Rollup Processing Rules
tab in Labor Rule Maintenance
, the system logs the following against the user’s default LCC, IDLE_TIME
:
Time between clock in and the labor on to the first SFC number
Time between the labor off from one SFC number and the labor on to another
Time between the labor off from the last SFC number and clock out
The system logs the time between the labor on to and labor off from an SFC number against the respective SFC LCC. The system associates this time with the user.
If you selected the Enable SFC Labor Summarization
checkbox on the Rollup Processing Rules
tab page in Labor Rule Maintenance
, the system logs the time between the labor on to and labor on from each
SFC number against the SFC LCCs.
Prerequisites:
You have set the Idle Factor for Labor Time
field to Labor on to Labor on
on the Rollup Processing Rules
tab page in Labor Rule Maintenance
.
You have created an indirect user LCC in Labor Charge Code Maintenance
named IDLE_TIME
, and this is the default user LCC for the operators in this example.
You have set up Labor on
to run on Start
and Labor off
to run on Complete
in POD Maintenance
.
The figure below illustrates Example 2
and is followed by an explanation:
A production operator clocks in at the beginning of the shift, and the system starts charging time against IDLE_TIME
. At the workstation, the operator works one SFC number at a time in the POD. The operator clocks out at the end of the shift without changing the
user LCC during the shift.
If you selected the Enable User Labor Summarization
checkbox on the Rollup Processing Rules
tab page in Labor Rule Maintenance
, the system logs the following against the user’s default LCC, IDLE_TIME
:
The time between clock in and the labor on to the first SFC number
The time between the labor off from the last SFC number and clock out
The system logs the time between the labor off from one SFC number and the labor on to the next SFC number against the previous SFC LCC. The system associates this time with the user.
If you selected the Enable SFC Labor Summarization
checkbox on the Rollup Processing Rules
tab page in Labor Rule Maintenance
, the system logs the total time between the labor on to one SFC number and
the labor off from the next SFC number against the first SFC LCC.
Prerequisites
On the Rollup Processing Rules
tab page in Labor Rule Maintenance
, you have set the Idle Factor for Labor Time
field to Labor on to Labor off
.
You have set up Labor Tracking
with no clock in required.
You have selected the Enable SFC Labor Summarization
checkbox, and cleared the Enable User Labor Summarization
checkbox on the Rollup Processing Rules
tab in Labor Rule Maintenance
.
You have set up Labor on
to run on Start
and Labor off
to run on Complete
in POD Maintenance
.
The figure below illustrates Example 3
and is followed by an explanation:
Without clocking in or clocking out, a production operator works one SFC number at a time in the POD.
Without clocking in or clocking out, the system does not count user labor results.
The system logs the time between the labor on and labor off to or from each SFC number against the SFC LCCs.