Show TOC

Background documentationMobile Data Collection

 

You use this activity to enter values for data parameters and user-defined fields associated with DC groups for SFC numbers, resources, or work centers in the Mobile POD (see Mobile POD).

Rules

The following tables describe rules and settings that you can change for this activity (MOBILE_DC) in Activity Maintenance:

Rule

Setting

AUTO_NEXT

YES: The next available, not selected DC group is automatically displayed

NO (default): Only the selected DC groups are displayed

ENFORCE_GROUP_MODE

Controls the behavior when a DC group of the selected SFC number has the Manual-Multiple collection method but the SFC numbers do not meet the criteria for the Manual-Multiple mode

YES: Displays an error message

NO (default): The Manual-Single mode is used for the DC group

LOGNC_ID_ON_GROUP_FAILURE

NONE or blank (default): The system does not open Mobile Log NC when a DC group fails (see Mobile Log NC)

PROCESS_ALL_DC_GROUPS

TRUE (default): The system simultaneously displays all DC groups that are to collect data for the SFC number at this attachment point

FALSE: The system displays DC groups one at a time to collect data for the SFC number at this attachment point

SHOW_APPLY_TO_ALL

Controls whether the Apply to All SFCs checkbox is visible when you collect data in the Manual-Multiple mode

YES (default): The Apply to all SFCs checkbox is visible. You may deselect the checkbox to switch from the Manual-Multiple mode to the Manual-Single mode.

NO: The Apply to All SFCs checkbox is not visible and you must collect data in the Manual-Multiple mode.

More Information

Data Collection Entry