Configuring an Equipment Status Filter for an Equipment Table

Prerequisites

Address the following items before performing the procedure:

  • Know the status or statuses that you are filtering on for equipment synchronization, as they are used in the procedure

  • Have access to the ConfigPanel and permissions to change configuration settings

Context

Use the following procedure to create a filter rule for the OMDO, SAM2210_EQUIPMENT. Specifically, you are adding a rule to the filter EQUI_INCL_SYST_STAT. After you add the filter rule, only the equipment records that match the ones configured in the rule are downloaded to the SAP Asset Manager client.

Procedure

  1. Navigate to Start of the navigation pathConfigPanel Home Next navigation step OData Mobile Data Object ConfigurationEnd of the navigation path.
  2. Select your application in the Mobile Application Filter field.

    Selecting an application filters the OData Mobile Data Object by Mobile App choices in the left panel with only OMDOs available in your application.

  3. View the new OMDO copy by selecting it in the OData Mobile Data Object by Mobile App list.
  4. Select the Data Filter tab.
  5. In the Defined Filters list, click the Start of the navigation pathOperation - READ Next navigation step Standard Filter Next navigation step EQUI_INCL_USER_STATEnd of the navigation path node.
  6. Add a rule to the filter with the following configuration settings:
    • Filter Rule Type: Static Value in Range Format

    • Sign: Inclusive

    • Option: =

    • Low Value: Equipment status to filter on

    • Active Flag: Checked

  7. Repeat the previous step to include additional statuses in the filter.
  8. Save your changes.

Results

When you finish the procedure, the equipment records downloaded by the SAP Asset Manager application are filtered to only include records with the status or statuses configured in the filter rules.

Next Steps

You may need to filter equipment according to additional criteria. Test that the status filters created during this procedure are performing as expected before creating additional filters for the same data set. Regardless of additional changes, test the synchronization of the equipment data thoroughly after you modify the application.