Join Control
Definition
Part of the InfoSet Builder screen. The InfoProviders that are included in the join are displayed in the join control.
Use
In the join control, you define the join conditions. Valid join conditions are a prerequisite for the system to be able to activate the InfoSet. More information: Defining Join Conditions.
The first time you call the InfoSet Builder you can choose between two display modes:
network (DataFlowControl) or tree (TreeControl). While the network display is clearer, the tree display can be read by the screen reader and is thus better suited for visually-impaired users. You can change this setting at any time by choosing . The change takes effect the next time you call the InfoSet Builder.
Structure
The same functions are available in both display modes. However, the network display is more commonly used, as it gives a clearer overview. This is why the differences between the tree display and the network display are only briefly addressed here. After this section, only the network display will be described.
Special Features of the Tree Display
The InfoProvider is displayed in a tree structure in the join control. The
symbol indicates the option of a time dependency. An existing left outer join is indicated using a
flag. You can display a join in the right side of the screen by double-clicking an InfoObject. You can set the join condition with the Selection flag.
Displaying an InfoProvider in the Join Control
InfoProviders are displayed as a table in the join control. A
symbol in the header indicates that an InfoProvider is time-dependent. The inactive version of this symbol indicates the option of a time dependency.
Depending on the type of InfoProvider, the following information is displayed in the rows of the table:
-
For DataStore objects and InfoCubes: A field (key field or data field) for each one, plus a dimension row for InfoCubes
-
For InfoObjects: the InfoObject itself, plus compound characteristics or an attribute
InfoObjects are described as follows in the columns of the table:
|
Column |
What you need to know |
|
Use Field |
Field selection for an InfoSet: If this flag is selected, the relevant field or attribute of an InfoProvider is released for use in reporting. This means that it can be used in BEx Query Designer for defining queries. In the default setting, this flag is selected. You can restrict the number of available fields or attributes from an InfoProvider by deselecting this flag. |
|
Key Field, Additional Field, Dimension |
The
The |
|
Technical name |
|
|
Object type (represented by the corresponding symbol) |
Examples:
|
|
Description |
Long Text Description |
|
Key Date |
This column is only filled for D type (date) fields or attributes of an InfoProvider, and for time characteristics, from which a key date is derived (0CALWEEK, 0CALMONTH, 0CALQUARTER, 0CALYEAR, 0FISCPER, 0FISCYEAR). If the indicator is set in this checkbox, the InfoObject is used as a temporal operand. In the default setting, this flag is not selected. If it is selectedt, and a key date can be derived, the additional fields mentioned above are added to the InfoProvider. See Temporal Joins. |
The following functions are available from the context menu of a table entry:
-
Define Time-Dependency
This enables you to define valid time intervals. The appropriate characteristics are offered to you using input help. More information: Temporal Joins.
-
Request Status
This function is only available for InfoCubes. More information: Special Features of InfoCubes in InfoSets.
-
Delete Object
Choose this function to delete an object from the join control.
-
Left Outer Join or Inner Join
For more information on the left outer join operator, see Defining Join Conditions.
-
Select All Fields
If you choose this option, all fields or attributes of an InfoProvider are released for reporting. The flags are selected in the Use Field column accordingly.
-
Deselect All Fields
If you choose this option, all flags are deselected in the Use Field column.
Displaying Join Conditions in the Join Control
A join condition is displayed as a line that connects exactly one InfoObject within a row from one object, with exactly one InfoObject within a row from another object.
More information: Defining Join Conditions.
Navigating in the Join Control
Location of the individual objects
The system inserts each object from a fixed, predetermined default size into the join control.
Size of the individual objects
Clicking the
icon enlarges the view by 10%.
Clicking the
icon reduces the view by 10%.
The
function automatically arranges the objects to provide an overview.
Navigator
By pressing
you can access navigation help.
This function can also be called from the context menu for the join control.
-
If you want to change the section of the screen to be displayed, move the red frame in the navigator.
-
If you want to change the size of the objects, adjust the dimensions of the frame itself:
Reducing the frame has the same effect as the zoom-in function.
Enlarging the frame has the same effect as the zoom-out function.
Changing Descriptions
The descriptive texts that are used in the metadata repository for the InfoProviders and their attributes are also used in the join control.
If you use InfoProviders or InfoObjects more than once as attributes in the join, it helps if you change the descriptive texts for the purposes of the InfoSet. This enables you to identify the individual objects more easily.
Choose
. An overview of all the texts is displayed beneath the join control. You can change any of these texts.
The following functions are available:
|
Function |
What you need to know |
|
|
A selection of the texts for
|
|
|
Adds the texts to the display in the join control. |
|
|
Undoes the changes made to the texts. If you then click |
Delete
Select the object(s) that you want to delete from the join and choose
.
Saving a Join as a .jpg File
Choose
to save your join definition on a PC as a graphic in jpeg format.
To print a copy of your join definition, choose
.

You can use this function to show alias names for fields and tables / InfoProviders. These alias names are required in InfoSets, to be able to map self joins for example. Field alias names start with F and are followed by a five digit number starting with 1. The names are numbered sequentially. Table alias names start with T and are followed by a number starting with 1. They are also numbered sequentially. In both cases, the highest possible number is 99999.


designates the following:
symbol designates additional attributes for time-dependent InfoObjects
symbol indicates an InfoCube dimension