Testing a Multiple Call Destination System

Use

The PCo Management Console offers a test function for the multiple call destination system. You can use this function to test a multiple call destination system without having to include this destination system in an agent instance with a notification.

Prerequisites

  • You have configured a multiple call destination system and resolved all the configuration errors of the multiple call destination system displayed by the PCo Management Console.

  • You have saved all changes that you made within the PCo Management Console.

  • If you call other destination systems from your multiple call destination system that require a running PCo agent instance, for example, a query destination system or an OPC UA destination system, you start these agent instances before the test.

  • If you call other destination systems from your multiple call destination system that require a running server, for example, a Web server, you make sure that these servers are available.

Procedure

Test Configuration

  1. Choose Test Configuration on the Destination System Calls tab.

    The Test Configuration dialog box appears.

  2. Enter values for the input variables of your multiple call destination system in the Variables table.

  3. Choose the log level.

  4. Choose Run / Continue to End to run the multiple call destination system without interruption.

  5. Choose Run in Debug Mode / Continue to Next Message to execute the multiple call destination system step by step from log message to log message.

    The system executes the next steps without interruption to the end.

  6. To switch off the debug mode, choose Run / Continue to End.

    The next steps are then executed without interruption to the end.

  7. If the multiple call destination system no longer responds during execution, or if you want to end execution in debug mode, choose Stop Debugging.

  8. If you choose Reset Variable Values after the test, the values of the output variables and local variables as well as the update count of all variables are reset first.

  9. If you choose Reset Variable Values again, the values of the input variables are deleted.

Screen Area: Variables

During and after execution of the test, you see the values and the update count for the input variables, output variables, and local variables of the multiple call destination system in the Variables screen area.

Screen Area: Log Messages

You can see the following information in the Log Messages screen area:

  • Execution of the multiple call destination system

  • Total duration of the test run (after successful execution)

If you choose Copy Log Messages to Clipboard, all displayed log messages are copied to the Windows clipboard. From there, you can insert the messages in an external text editor, for example.