Adding a PCo System via SLD

Prerequisites

You have carried out an SLD registration. See also: Registering PCo in the SLD

Context

This function provides you with an overview of all existing PCo systems in the system landscape.

Procedure

  1. In the Remote Client, click on SAP Plant Connectivity Systems. From the menu, choose Start of the navigation pathAction Next navigation step Add System to MonitoringEnd of the navigation path.

    The Plant Connectivity Remote Client Settings dialog box appears.

  2. Choose the Use SLD function key.

    A new dialog box appears.

  3. In the SLD URL field, enter the URL and the port for the System Landscape Directory (for example, http://pwdf6412.wdf.sap.corp. 50000), and enter the user name and password.
  4. Choose the Read Registered Systems function key.

    The system displays a list of PCo systems.

  5. Select a PCo system and choose the Select System function key.

    The Plant Connectivity Remote Client Settings dialog box appears.

  6. Here, check that Windows and Use SSL are selected.
  7. Choose the Call System Information function key. If required, change the description of the system to be added.
  8. If the selected PCo system is connected, the Add System function key is active and you can add the system.
  9. Repeat the steps to add further PCo systems to the remote client.

Results

The selected PCo systems are displayed in the Remote Client with their agent instances.