The Load Restart Process Recovery

You are in the process of loading data into Data Hub when the power supply fails in your server. How does Data Hub respond to this situation? Upon server restart, Data Hub cleans up the Data Loading Action, and you are then free to reinitiate the data load.

When data loading is started into Data Hub, a Data Loading Action is initiated. If the server fails during the data loading process, the Load Action status is IN_PROGRESS. However, only some of the individual items of the load action are marked as PENDING, which represents an incomplete load. Data Hub does not resume processing until the recovery actions are complete. The load restart process recovery works as follows:
  1. During the server restart, Data Hub recognizes there is a Data Loading Action with an IN_PROGRESS status.
  2. It sets the status of the Data Loading Action to FAILURE.
  3. It deletes all raw items associated with the Data Loading Action marked as FAILURE.

    At this point, start your data loading process again from the beginning.