Creating Environmental Limits
Prerequisites
-
You have prepared the environment management master data in the system. Depending on the limit that you wish to create, you must have created one of the following: chemicals (mixtures or listed substances) or physical parameters.
For more information about environmental management master data, see: Preparing Locations and Chemical Data for Environment Management.
-
You have specified environmental limit types in Customizing for .
Context
You can use environmental limits to define compliance checks on the environmental data (collected or calculated) within your compliance requirement paragraphs. You can define multiple environmental limits depending on your business case, specific requirements, or the installed equipment.
An environmental limit denotes an environmentally-relevant threshold that can be related to the collected or calculated data. After the limit is set, the corresponding data is verified against it and the system automatically determines whether the data is within the range, approaches the limit, or exceeds it. This way, the environmental manager can easily identify any inconsistencies related to the environmental data and can address these accordingly.
The environmental limits conform to the lifecycle of the compliance requirement. When the requirement is released, the environmental limit is also released for active usage.
For more information, see: Editing Compliance Requirements.
Procedure
Example
You want to detect a leakage at a newly installed device by performing acoustic leak detection. Such a detection requirement is described in regulation Title 40 Protection of Environment under . In this case, after you created the compliance requirement in the system and organized its contents, you can define an environmental limit within the requirement paragraph to automatically check the collected data against the predefined limit.
You create an environmental limit with the following details:
-
Limit Type:Upper Limit
-
Unit: scf (standard cubic feet)
-
Upper Limit Value: 3.1
-
Upper Warning Value: 2.8
If the collected value is within the range formed by the warning and limit values (2.8 scf - 3.1 scf) the system indicates that the limit is nearly approached and marks the data as Warning. If the data is greater than the limit (3.1 scf), it is marked as Exceedance (in this particular case a leakage is detected), and the environmental manager must take the necessary measures immediately.
For more information, see: Monitoring Environmental Data.