icm/wp_roll_timeout

Use

You use this parameter to determine the maximum time that a work process can run on the ICM when reading data, before the user context is rolled out.

With slow network connections and large volumes of data, the read time can become very slow (> 600 seconds). This parameter can prevent the work process from being blocked for a long period of time, even through it can only read small datasets. The context is then rolled out and the work process is available for other tasks. The data affected can be collected in an MPI and then fetched by a work process.

Structure

Work area

Internet Communication Manager

Unit

Integer value (seconds)

Default value

15

Dynamically changeable

Local and on all servers

Value Range and Syntax

You can specify values between 5 and 3600 (between 5 seconds and one hour).