public class InspectionResult extends VdmEntity<InspectionResult>
Modifier and Type | Class and Description |
---|---|
static class |
InspectionResult.InspectionResultBuilder |
Modifier and Type | Field and Description |
---|---|
static InspectionResultSelectable |
ALL_FIELDS
Selector for all available fields of InspectionResult.
|
static InspectionResultField<String> |
CHARACTERISTIC_ATTRIBUTE_CATALOG
Use with available fluent helpers to apply the CharacteristicAttributeCatalog field to query operations.
|
static InspectionResultField<String> |
CHARACTERISTIC_ATTRIBUTE_CODE
Use with available fluent helpers to apply the CharacteristicAttributeCode field to query operations.
|
static InspectionResultField<String> |
CHARACTERISTIC_ATTRIBUTE_CODE_GRP
Use with available fluent helpers to apply the CharacteristicAttributeCodeGrp field to query operations.
|
static InspectionResultField<String> |
CREATED_BY_USER
Use with available fluent helpers to apply the CreatedByUser field to query operations.
|
static InspectionResultField<Calendar> |
CREATION_DATE
Use with available fluent helpers to apply the CreationDate field to query operations.
|
static InspectionResultField<String> |
INSP_PLAN_OPERATION_INTERNAL_ID
Use with available fluent helpers to apply the InspPlanOperationInternalID field to query operations.
|
static InspectionResultField<String> |
INSP_RESULT_HAS_MAXIMUM_VALUE
Use with available fluent helpers to apply the InspResultHasMaximumValue field to query operations.
|
static InspectionResultField<String> |
INSP_RESULT_HAS_MINIMUM_VALUE
Use with available fluent helpers to apply the InspResultHasMinimumValue field to query operations.
|
static InspectionResultField<Integer> |
INSP_RESULT_VALID_VALUES_NUMBER
Use with available fluent helpers to apply the InspResultValidValuesNumber field to query operations.
|
static InspectionResultField<Double> |
INSP_RESULT_VARIANCE
Use with available fluent helpers to apply the InspResultVariance field to query operations.
|
static InspectionResultField<Double> |
INSP_RSLT_ABOVE_TOLERANCE_FRACTION
Use with available fluent helpers to apply the InspRsltAboveToleranceFraction field to query operations.
|
static InspectionResultField<Integer> |
INSP_RSLT_ABOVE_TOLERANCE_VALS_NMBR
Use with available fluent helpers to apply the InspRsltAboveToleranceValsNmbr field to query operations.
|
static InspectionResultField<Double> |
INSP_RSLT_BELOW_TOLERANCE_FRACTION
Use with available fluent helpers to apply the InspRsltBelowToleranceFraction field to query operations.
|
static InspectionResultField<Integer> |
INSP_RSLT_BELOW_TOLERANCE_VALS_NMBR
Use with available fluent helpers to apply the InspRsltBelowToleranceValsNmbr field to query operations.
|
static InspectionResultField<String> |
INSP_RSLT_FREE_DEFINED_TEST_EQUIP
Use with available fluent helpers to apply the InspRsltFreeDefinedTestEquip field to query operations.
|
static InspectionResultField<Integer> |
INSP_RSLT_NONCONFORMING_VALS_NMBR
Use with available fluent helpers to apply the InspRsltNonconformingValsNmbr field to query operations.
|
static InspectionResultField<String> |
INSPECTION_CHARACTERISTIC
Use with available fluent helpers to apply the InspectionCharacteristic field to query operations.
|
static InspectionResultField<String> |
INSPECTION_LOT
Use with available fluent helpers to apply the InspectionLot field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_ATTRIBUTE
Use with available fluent helpers to apply the InspectionResultAttribute field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_CATALOG2
Use with available fluent helpers to apply the InspectionResultCatalog2 field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_CATALOG3
Use with available fluent helpers to apply the InspectionResultCatalog3 field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_CATALOG4
Use with available fluent helpers to apply the InspectionResultCatalog4 field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_CATALOG5
Use with available fluent helpers to apply the InspectionResultCatalog5 field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_CODE_GROUP2
Use with available fluent helpers to apply the InspectionResultCodeGroup2 field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_CODE_GROUP3
Use with available fluent helpers to apply the InspectionResultCodeGroup3 field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_CODE_GROUP4
Use with available fluent helpers to apply the InspectionResultCodeGroup4 field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_CODE_GROUP5
Use with available fluent helpers to apply the InspectionResultCodeGroup5 field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_CODE2
Use with available fluent helpers to apply the InspectionResultCode2 field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_CODE3
Use with available fluent helpers to apply the InspectionResultCode3 field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_CODE4
Use with available fluent helpers to apply the InspectionResultCode4 field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_CODE5
Use with available fluent helpers to apply the InspectionResultCode5 field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_HAS_LONG_TEXT
Use with available fluent helpers to apply the InspectionResultHasLongText field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_HAS_MEAN_VALUE
Use with available fluent helpers to apply the InspectionResultHasMeanValue field to query operations.
|
static InspectionResultField<Double> |
INSPECTION_RESULT_MAXIMUM_VALUE
Use with available fluent helpers to apply the InspectionResultMaximumValue field to query operations.
|
static InspectionResultField<Double> |
INSPECTION_RESULT_MEAN_VALUE
Use with available fluent helpers to apply the InspectionResultMeanValue field to query operations.
|
static InspectionResultField<Double> |
INSPECTION_RESULT_MINIMUM_VALUE
Use with available fluent helpers to apply the InspectionResultMinimumValue field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_ORIGIN
Use with available fluent helpers to apply the InspectionResultOrigin field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_ORIGINAL_VALUE
Use with available fluent helpers to apply the InspectionResultOriginalValue field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_STATUS
Use with available fluent helpers to apply the InspectionResultStatus field to query operations.
|
static InspectionResultField<String> |
INSPECTION_RESULT_TEXT
Use with available fluent helpers to apply the InspectionResultText field to query operations.
|
static InspectionResultField<String> |
INSPECTION_VALUATION_RESULT
Use with available fluent helpers to apply the InspectionValuationResult field to query operations.
|
static InspectionResultField<String> |
INSPECTOR
Use with available fluent helpers to apply the Inspector field to query operations.
|
static InspectionResultField<Calendar> |
LAST_CHANGE_DATE
Use with available fluent helpers to apply the LastChangeDate field to query operations.
|
static InspectionResultField<String> |
LAST_CHANGED_BY_USER
Use with available fluent helpers to apply the LastChangedByUser field to query operations.
|
Constructor and Description |
---|
InspectionResult() |
InspectionResult(String inspectionLot,
String inspPlanOperationInternalID,
String inspectionCharacteristic,
String inspector,
String inspectionResultStatus,
String inspectionResultAttribute,
String inspectionResultOrigin,
String inspectionValuationResult,
Double inspectionResultMeanValue,
String inspectionResultHasMeanValue,
Double inspectionResultMaximumValue,
String inspResultHasMaximumValue,
Double inspectionResultMinimumValue,
String inspResultHasMinimumValue,
String inspectionResultOriginalValue,
Integer inspResultValidValuesNumber,
String inspectionResultText,
String inspectionResultHasLongText,
String characteristicAttributeCodeGrp,
String characteristicAttributeCode,
String inspRsltFreeDefinedTestEquip,
Integer inspRsltBelowToleranceValsNmbr,
Integer inspRsltAboveToleranceValsNmbr,
Integer inspRsltNonconformingValsNmbr,
Double inspRsltAboveToleranceFraction,
Double inspRsltBelowToleranceFraction,
Double inspResultVariance,
String characteristicAttributeCatalog,
String inspectionResultCatalog2,
String inspectionResultCatalog3,
String inspectionResultCatalog4,
String inspectionResultCatalog5,
String inspectionResultCode2,
String inspectionResultCode3,
String inspectionResultCode4,
String inspectionResultCode5,
String inspectionResultCodeGroup2,
String inspectionResultCodeGroup3,
String inspectionResultCodeGroup4,
String inspectionResultCodeGroup5,
String createdByUser,
Calendar creationDate,
String lastChangedByUser,
Calendar lastChangeDate,
ErpConfigContext erpConfigContext) |
Modifier and Type | Method and Description |
---|---|
static InspectionResult.InspectionResultBuilder |
builder() |
boolean |
equals(Object o) |
static <T> InspectionResultField<T> |
field(String fieldName,
Class<T> fieldType)
Use with available fluent helpers to apply an extension field to query operations.
|
String |
getCharacteristicAttributeCatalog()
Constraints: Not nullable, Maximum length: 1 If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
|
String |
getCharacteristicAttributeCode()
Constraints: Not nullable, Maximum length: 4 The code can be uniquely identified only with the catalog type and code group.
|
String |
getCharacteristicAttributeCodeGrp()
Constraints: Not nullable, Maximum length: 8
|
String |
getCreatedByUser()
Constraints: Not nullable, Maximum length: 12 The system automatically enters the user name.
|
Calendar |
getCreationDate()
Constraints: Not nullable, Precision: 0 The system enters the current system date.
|
ErpConfigContext |
getErpConfigContext()
Convienence field for reusing the same ERP system context with multiple queries (e.g. fetching associated entities).
|
String |
getInspectionCharacteristic()
(Key Field) Constraints: Not nullable, Maximum length: 4
|
String |
getInspectionLot()
(Key Field) Constraints: Not nullable, Maximum length: 12 The inspection lot number is assigned by the system.
|
String |
getInspectionResultAttribute()
Constraints: Not nullable, Maximum length: 1 The system calculates statistics, such as the mean value, standard deviation and the number of fields only from valid single results.When you indicate that the result of a partial sample is invalid, the system reduces the summarized results data of the inspection characteristic by the results data of the invalid partial sample.
|
String |
getInspectionResultCatalog2()
Constraints: Not nullable, Maximum length: 1 If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
|
String |
getInspectionResultCatalog3()
Constraints: Not nullable, Maximum length: 1 If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
|
String |
getInspectionResultCatalog4()
Constraints: Not nullable, Maximum length: 1 If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
|
String |
getInspectionResultCatalog5()
Constraints: Not nullable, Maximum length: 1 If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
|
String |
getInspectionResultCode2()
Constraints: Not nullable, Maximum length: 4 The code can be uniquely identified only with the catalog type and code group.
|
String |
getInspectionResultCode3()
Constraints: Not nullable, Maximum length: 4 The code can be uniquely identified only with the catalog type and code group.
|
String |
getInspectionResultCode4()
Constraints: Not nullable, Maximum length: 4 The code can be uniquely identified only with the catalog type and code group.
|
String |
getInspectionResultCode5()
Constraints: Not nullable, Maximum length: 4 The code can be uniquely identified only with the catalog type and code group.
|
String |
getInspectionResultCodeGroup2()
Constraints: Not nullable, Maximum length: 8
|
String |
getInspectionResultCodeGroup3()
Constraints: Not nullable, Maximum length: 8
|
String |
getInspectionResultCodeGroup4()
Constraints: Not nullable, Maximum length: 8
|
String |
getInspectionResultCodeGroup5()
Constraints: Not nullable, Maximum length: 8
|
String |
getInspectionResultHasLongText()
Constraints: Not nullable, Maximum length: 1
|
String |
getInspectionResultHasMeanValue()
Constraints: Not nullable, Maximum length: 1 If this indicator is set, then the value of the corresponding numeric field is not initial.
|
Double |
getInspectionResultMaximumValue()
Constraints: noneIf summarized results recording is defined for an inspection characteristic and the field is ready for input, enter the maximum value of the valid measured values.For characteristics with single-value recording the system automatically determines the maximum value of the valid measured values that were confirmed, if youselect the function for calculating statistical momentsvaluate the characteristic (partial sample)
|
Double |
getInspectionResultMeanValue()
Constraints: noneIf summarized results recording is defined for an inspection characteristic and the field is ready for input, enter the mean value of the valid measured values.For characteristics with single-value recording the system automatically determines the mean value after each entry.
|
Double |
getInspectionResultMinimumValue()
Constraints: noneIf summarized results recording is defined for an inspection characteristic and the field is ready for input, enter the minimum value of the valid measured values.For characteristics with single-value recording the system automatically determines the minimum value of the valid measured values that were confirmed, if youselect the function for calculating statistical momentsvaluate the characteristic (partial sample)
|
String |
getInspectionResultOrigin()
Constraints: Not nullable, Maximum length: 2 The keys for the origin of the results data are for information purposes only and have no controlling function.If a result is copied, for example from a certificate, this operation can be documented.
|
String |
getInspectionResultOriginalValue()
Constraints: Not nullable, Maximum length: 25
|
String |
getInspectionResultStatus()
Constraints: Not nullable, Maximum length: 1 To display a list of all processing statuses that are possible for a characteristic or a sample, select the possible entries help.If you carry out one of the following functions, the processing status of the characteristic changes:enter data in the recording screen for the characteristic (sample):the processing status changes to 'processing'set for processing:the processing status changes to 'processing'valuate:the processing status changes to 'valuated'close:the processing status changes to 'closed'You can enter data or calculate statistics only while the inspection characteristic (or sample) status is set for processing.If you set a characteristic (sample) that has not yet been processed to 'processed', you have to close this characteristic (sample).
|
String |
getInspectionResultText()
Constraints: Not nullable, Maximum length: 40
|
String |
getInspectionValuationResult()
Constraints: Not nullable, Maximum length: 1 For the valuation of the characteristic a distinction is made between the acceptance decision for the inspected units and the impact on similar future inspections (dynamic modification of samples).To display a list of all possible values for the valuation of the characteristic (or partial sample), select the list function.
|
String |
getInspector()
Constraints: Not nullable, Maximum length: 12 The system does not check the entries made.
|
String |
getInspPlanOperationInternalID()
(Key Field) Constraints: Not nullable, Maximum length: 8
|
String |
getInspResultHasMaximumValue()
Constraints: Not nullable, Maximum length: 1 If this indicator is set, then the value of the corresponding numeric field is not initial.
|
String |
getInspResultHasMinimumValue()
Constraints: Not nullable, Maximum length: 1 If this indicator is set, then the value of the corresponding numeric field is not initial.
|
Integer |
getInspResultValidValuesNumber()
Constraints: noneIf the field is ready for input, enter the inspected sample size.For each inspection plan characteristic you define the amount by which the inspected sample size in the 'Insp.ed' field can deviate from the to-be-inspected sample size in the 'Inspect' field.
|
Double |
getInspResultVariance()
Constraints: noneFor inspection characteristics with single-value recording the system determines the standard deviation of the confirmed and valid measured values if youselect the function for calculating statistical moments --OR--valuate the inspection characteristic (partial sample)
|
Double |
getInspRsltAboveToleranceFraction()
Constraints: noneThe share is displayed in per cent.
|
Integer |
getInspRsltAboveToleranceValsNmbr()
Constraints: noneThe system determines the number of nonconforming single values for the inspection characteristic or the partial sample from the number of valid single values outside the tolerance range.If the field is ready for input and the characteristic has an upper tolerance limit, you enter the number of measured values above the tolerance range.
|
Double |
getInspRsltBelowToleranceFraction()
Constraints: noneThe share is displayed in per cent.
|
Integer |
getInspRsltBelowToleranceValsNmbr()
Constraints: noneThe system determines the number of nonconforming single values for the inspection characteristic or the partial sample from the number of valid single values outside the tolerance range.If the field is ready for input and the characteristic has a lower tolerance limit, you enter the number of measured values below the tolerance range.
|
String |
getInspRsltFreeDefinedTestEquip()
Constraints: Not nullable, Maximum length: 18 The number of the machine used to produce the partThe test equipment used for the inspectionYou can use the input help to search for and select an equipment master record or a production resources and tools master record.
|
Integer |
getInspRsltNonconformingValsNmbr()
Constraints: noneIf the field is ready for input, enter the number of nonconforming sample units.The number of nonconforming sample units cannot be greater than the number of inspected test units that can be confirmed as the number of valid measured values.
|
Calendar |
getLastChangeDate()
Constraints: Not nullable, Precision: 0 The system enters the current system date.
|
String |
getLastChangedByUser()
Constraints: Not nullable, Maximum length: 12
|
Class<InspectionResult> |
getType() |
int |
hashCode() |
void |
setCharacteristicAttributeCatalog(String characteristicAttributeCatalog)
Constraints: Not nullable, Maximum length: 1 If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
|
void |
setCharacteristicAttributeCode(String characteristicAttributeCode)
Constraints: Not nullable, Maximum length: 4 The code can be uniquely identified only with the catalog type and code group.
|
void |
setCharacteristicAttributeCodeGrp(String characteristicAttributeCodeGrp)
Constraints: Not nullable, Maximum length: 8
|
void |
setCreatedByUser(String createdByUser)
Constraints: Not nullable, Maximum length: 12 The system automatically enters the user name.
|
void |
setCreationDate(Calendar creationDate)
Constraints: Not nullable, Precision: 0 The system enters the current system date.
|
void |
setErpConfigContext(ErpConfigContext erpConfigContext)
Convienence field for reusing the same ERP system context with multiple queries (e.g. fetching associated entities).
|
void |
setInspectionCharacteristic(String inspectionCharacteristic)
(Key Field) Constraints: Not nullable, Maximum length: 4
|
void |
setInspectionLot(String inspectionLot)
(Key Field) Constraints: Not nullable, Maximum length: 12 The inspection lot number is assigned by the system.
|
void |
setInspectionResultAttribute(String inspectionResultAttribute)
Constraints: Not nullable, Maximum length: 1 The system calculates statistics, such as the mean value, standard deviation and the number of fields only from valid single results.When you indicate that the result of a partial sample is invalid, the system reduces the summarized results data of the inspection characteristic by the results data of the invalid partial sample.
|
void |
setInspectionResultCatalog2(String inspectionResultCatalog2)
Constraints: Not nullable, Maximum length: 1 If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
|
void |
setInspectionResultCatalog3(String inspectionResultCatalog3)
Constraints: Not nullable, Maximum length: 1 If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
|
void |
setInspectionResultCatalog4(String inspectionResultCatalog4)
Constraints: Not nullable, Maximum length: 1 If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
|
void |
setInspectionResultCatalog5(String inspectionResultCatalog5)
Constraints: Not nullable, Maximum length: 1 If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
|
void |
setInspectionResultCode2(String inspectionResultCode2)
Constraints: Not nullable, Maximum length: 4 The code can be uniquely identified only with the catalog type and code group.
|
void |
setInspectionResultCode3(String inspectionResultCode3)
Constraints: Not nullable, Maximum length: 4 The code can be uniquely identified only with the catalog type and code group.
|
void |
setInspectionResultCode4(String inspectionResultCode4)
Constraints: Not nullable, Maximum length: 4 The code can be uniquely identified only with the catalog type and code group.
|
void |
setInspectionResultCode5(String inspectionResultCode5)
Constraints: Not nullable, Maximum length: 4 The code can be uniquely identified only with the catalog type and code group.
|
void |
setInspectionResultCodeGroup2(String inspectionResultCodeGroup2)
Constraints: Not nullable, Maximum length: 8
|
void |
setInspectionResultCodeGroup3(String inspectionResultCodeGroup3)
Constraints: Not nullable, Maximum length: 8
|
void |
setInspectionResultCodeGroup4(String inspectionResultCodeGroup4)
Constraints: Not nullable, Maximum length: 8
|
void |
setInspectionResultCodeGroup5(String inspectionResultCodeGroup5)
Constraints: Not nullable, Maximum length: 8
|
void |
setInspectionResultHasLongText(String inspectionResultHasLongText)
Constraints: Not nullable, Maximum length: 1
|
void |
setInspectionResultHasMeanValue(String inspectionResultHasMeanValue)
Constraints: Not nullable, Maximum length: 1 If this indicator is set, then the value of the corresponding numeric field is not initial.
|
void |
setInspectionResultMaximumValue(Double inspectionResultMaximumValue)
Constraints: noneIf summarized results recording is defined for an inspection characteristic and the field is ready for input, enter the maximum value of the valid measured values.For characteristics with single-value recording the system automatically determines the maximum value of the valid measured values that were confirmed, if youselect the function for calculating statistical momentsvaluate the characteristic (partial sample)
|
void |
setInspectionResultMeanValue(Double inspectionResultMeanValue)
Constraints: noneIf summarized results recording is defined for an inspection characteristic and the field is ready for input, enter the mean value of the valid measured values.For characteristics with single-value recording the system automatically determines the mean value after each entry.
|
void |
setInspectionResultMinimumValue(Double inspectionResultMinimumValue)
Constraints: noneIf summarized results recording is defined for an inspection characteristic and the field is ready for input, enter the minimum value of the valid measured values.For characteristics with single-value recording the system automatically determines the minimum value of the valid measured values that were confirmed, if youselect the function for calculating statistical momentsvaluate the characteristic (partial sample)
|
void |
setInspectionResultOrigin(String inspectionResultOrigin)
Constraints: Not nullable, Maximum length: 2 The keys for the origin of the results data are for information purposes only and have no controlling function.If a result is copied, for example from a certificate, this operation can be documented.
|
void |
setInspectionResultOriginalValue(String inspectionResultOriginalValue)
Constraints: Not nullable, Maximum length: 25
|
void |
setInspectionResultStatus(String inspectionResultStatus)
Constraints: Not nullable, Maximum length: 1 To display a list of all processing statuses that are possible for a characteristic or a sample, select the possible entries help.If you carry out one of the following functions, the processing status of the characteristic changes:enter data in the recording screen for the characteristic (sample):the processing status changes to 'processing'set for processing:the processing status changes to 'processing'valuate:the processing status changes to 'valuated'close:the processing status changes to 'closed'You can enter data or calculate statistics only while the inspection characteristic (or sample) status is set for processing.If you set a characteristic (sample) that has not yet been processed to 'processed', you have to close this characteristic (sample).
|
void |
setInspectionResultText(String inspectionResultText)
Constraints: Not nullable, Maximum length: 40
|
void |
setInspectionValuationResult(String inspectionValuationResult)
Constraints: Not nullable, Maximum length: 1 For the valuation of the characteristic a distinction is made between the acceptance decision for the inspected units and the impact on similar future inspections (dynamic modification of samples).To display a list of all possible values for the valuation of the characteristic (or partial sample), select the list function.
|
void |
setInspector(String inspector)
Constraints: Not nullable, Maximum length: 12 The system does not check the entries made.
|
void |
setInspPlanOperationInternalID(String inspPlanOperationInternalID)
(Key Field) Constraints: Not nullable, Maximum length: 8
|
void |
setInspResultHasMaximumValue(String inspResultHasMaximumValue)
Constraints: Not nullable, Maximum length: 1 If this indicator is set, then the value of the corresponding numeric field is not initial.
|
void |
setInspResultHasMinimumValue(String inspResultHasMinimumValue)
Constraints: Not nullable, Maximum length: 1 If this indicator is set, then the value of the corresponding numeric field is not initial.
|
void |
setInspResultValidValuesNumber(Integer inspResultValidValuesNumber)
Constraints: noneIf the field is ready for input, enter the inspected sample size.For each inspection plan characteristic you define the amount by which the inspected sample size in the 'Insp.ed' field can deviate from the to-be-inspected sample size in the 'Inspect' field.
|
void |
setInspResultVariance(Double inspResultVariance)
Constraints: noneFor inspection characteristics with single-value recording the system determines the standard deviation of the confirmed and valid measured values if youselect the function for calculating statistical moments --OR--valuate the inspection characteristic (partial sample)
|
void |
setInspRsltAboveToleranceFraction(Double inspRsltAboveToleranceFraction)
Constraints: noneThe share is displayed in per cent.
|
void |
setInspRsltAboveToleranceValsNmbr(Integer inspRsltAboveToleranceValsNmbr)
Constraints: noneThe system determines the number of nonconforming single values for the inspection characteristic or the partial sample from the number of valid single values outside the tolerance range.If the field is ready for input and the characteristic has an upper tolerance limit, you enter the number of measured values above the tolerance range.
|
void |
setInspRsltBelowToleranceFraction(Double inspRsltBelowToleranceFraction)
Constraints: noneThe share is displayed in per cent.
|
void |
setInspRsltBelowToleranceValsNmbr(Integer inspRsltBelowToleranceValsNmbr)
Constraints: noneThe system determines the number of nonconforming single values for the inspection characteristic or the partial sample from the number of valid single values outside the tolerance range.If the field is ready for input and the characteristic has a lower tolerance limit, you enter the number of measured values below the tolerance range.
|
void |
setInspRsltFreeDefinedTestEquip(String inspRsltFreeDefinedTestEquip)
Constraints: Not nullable, Maximum length: 18 The number of the machine used to produce the partThe test equipment used for the inspectionYou can use the input help to search for and select an equipment master record or a production resources and tools master record.
|
void |
setInspRsltNonconformingValsNmbr(Integer inspRsltNonconformingValsNmbr)
Constraints: noneIf the field is ready for input, enter the number of nonconforming sample units.The number of nonconforming sample units cannot be greater than the number of inspected test units that can be confirmed as the number of valid measured values.
|
void |
setLastChangeDate(Calendar lastChangeDate)
Constraints: Not nullable, Precision: 0 The system enters the current system date.
|
void |
setLastChangedByUser(String lastChangedByUser)
Constraints: Not nullable, Maximum length: 12
|
String |
toString() |
getCustomField, getCustomField, getCustomFieldNames, getCustomFields, hasCustomField, hasCustomField, setCustomField, setCustomField
public static final InspectionResultSelectable ALL_FIELDS
public static final InspectionResultField<String> INSPECTION_LOT
public static final InspectionResultField<String> INSP_PLAN_OPERATION_INTERNAL_ID
public static final InspectionResultField<String> INSPECTION_CHARACTERISTIC
public static final InspectionResultField<String> INSPECTOR
public static final InspectionResultField<String> INSPECTION_RESULT_STATUS
public static final InspectionResultField<String> INSPECTION_RESULT_ATTRIBUTE
public static final InspectionResultField<String> INSPECTION_RESULT_ORIGIN
public static final InspectionResultField<String> INSPECTION_VALUATION_RESULT
public static final InspectionResultField<Double> INSPECTION_RESULT_MEAN_VALUE
public static final InspectionResultField<String> INSPECTION_RESULT_HAS_MEAN_VALUE
public static final InspectionResultField<Double> INSPECTION_RESULT_MAXIMUM_VALUE
public static final InspectionResultField<String> INSP_RESULT_HAS_MAXIMUM_VALUE
public static final InspectionResultField<Double> INSPECTION_RESULT_MINIMUM_VALUE
public static final InspectionResultField<String> INSP_RESULT_HAS_MINIMUM_VALUE
public static final InspectionResultField<String> INSPECTION_RESULT_ORIGINAL_VALUE
public static final InspectionResultField<Integer> INSP_RESULT_VALID_VALUES_NUMBER
public static final InspectionResultField<String> INSPECTION_RESULT_TEXT
public static final InspectionResultField<String> INSPECTION_RESULT_HAS_LONG_TEXT
public static final InspectionResultField<String> CHARACTERISTIC_ATTRIBUTE_CODE_GRP
public static final InspectionResultField<String> CHARACTERISTIC_ATTRIBUTE_CODE
public static final InspectionResultField<String> INSP_RSLT_FREE_DEFINED_TEST_EQUIP
public static final InspectionResultField<Integer> INSP_RSLT_BELOW_TOLERANCE_VALS_NMBR
public static final InspectionResultField<Integer> INSP_RSLT_ABOVE_TOLERANCE_VALS_NMBR
public static final InspectionResultField<Integer> INSP_RSLT_NONCONFORMING_VALS_NMBR
public static final InspectionResultField<Double> INSP_RSLT_ABOVE_TOLERANCE_FRACTION
public static final InspectionResultField<Double> INSP_RSLT_BELOW_TOLERANCE_FRACTION
public static final InspectionResultField<Double> INSP_RESULT_VARIANCE
public static final InspectionResultField<String> CHARACTERISTIC_ATTRIBUTE_CATALOG
public static final InspectionResultField<String> INSPECTION_RESULT_CATALOG2
public static final InspectionResultField<String> INSPECTION_RESULT_CATALOG3
public static final InspectionResultField<String> INSPECTION_RESULT_CATALOG4
public static final InspectionResultField<String> INSPECTION_RESULT_CATALOG5
public static final InspectionResultField<String> INSPECTION_RESULT_CODE2
public static final InspectionResultField<String> INSPECTION_RESULT_CODE3
public static final InspectionResultField<String> INSPECTION_RESULT_CODE4
public static final InspectionResultField<String> INSPECTION_RESULT_CODE5
public static final InspectionResultField<String> INSPECTION_RESULT_CODE_GROUP2
public static final InspectionResultField<String> INSPECTION_RESULT_CODE_GROUP3
public static final InspectionResultField<String> INSPECTION_RESULT_CODE_GROUP4
public static final InspectionResultField<String> INSPECTION_RESULT_CODE_GROUP5
public static final InspectionResultField<String> CREATED_BY_USER
public static final InspectionResultField<Calendar> CREATION_DATE
public static final InspectionResultField<String> LAST_CHANGED_BY_USER
public static final InspectionResultField<Calendar> LAST_CHANGE_DATE
public InspectionResult()
public InspectionResult(@Nullable String inspectionLot, @Nullable String inspPlanOperationInternalID, @Nullable String inspectionCharacteristic, @Nullable String inspector, @Nullable String inspectionResultStatus, @Nullable String inspectionResultAttribute, @Nullable String inspectionResultOrigin, @Nullable String inspectionValuationResult, @Nullable Double inspectionResultMeanValue, @Nullable String inspectionResultHasMeanValue, @Nullable Double inspectionResultMaximumValue, @Nullable String inspResultHasMaximumValue, @Nullable Double inspectionResultMinimumValue, @Nullable String inspResultHasMinimumValue, @Nullable String inspectionResultOriginalValue, @Nullable Integer inspResultValidValuesNumber, @Nullable String inspectionResultText, @Nullable String inspectionResultHasLongText, @Nullable String characteristicAttributeCodeGrp, @Nullable String characteristicAttributeCode, @Nullable String inspRsltFreeDefinedTestEquip, @Nullable Integer inspRsltBelowToleranceValsNmbr, @Nullable Integer inspRsltAboveToleranceValsNmbr, @Nullable Integer inspRsltNonconformingValsNmbr, @Nullable Double inspRsltAboveToleranceFraction, @Nullable Double inspRsltBelowToleranceFraction, @Nullable Double inspResultVariance, @Nullable String characteristicAttributeCatalog, @Nullable String inspectionResultCatalog2, @Nullable String inspectionResultCatalog3, @Nullable String inspectionResultCatalog4, @Nullable String inspectionResultCatalog5, @Nullable String inspectionResultCode2, @Nullable String inspectionResultCode3, @Nullable String inspectionResultCode4, @Nullable String inspectionResultCode5, @Nullable String inspectionResultCodeGroup2, @Nullable String inspectionResultCodeGroup3, @Nullable String inspectionResultCodeGroup4, @Nullable String inspectionResultCodeGroup5, @Nullable String createdByUser, @Nullable Calendar creationDate, @Nullable String lastChangedByUser, @Nullable Calendar lastChangeDate, @Nullable ErpConfigContext erpConfigContext)
public Class<InspectionResult> getType()
getType
in class VdmObject<InspectionResult>
public static <T> InspectionResultField<T> field(String fieldName, Class<T> fieldType)
fieldName
- The name of the extension field as returned by the OData service.fieldType
- The Java type to use for the extension field when performing value comparisons.public static InspectionResult.InspectionResultBuilder builder()
@Nullable public String getInspectionLot()
The inspection lot number is assigned by the system.
@Nullable public String getInspPlanOperationInternalID()
@Nullable public String getInspectionCharacteristic()
@Nullable public String getInspector()
The system does not check the entries made.
@Nullable public String getInspectionResultStatus()
To display a list of all processing statuses that are possible for a characteristic or a sample, select the possible entries help.If you carry out one of the following functions, the processing status of the characteristic changes:enter data in the recording screen for the characteristic (sample):the processing status changes to 'processing'set for processing:the processing status changes to 'processing'valuate:the processing status changes to 'valuated'close:the processing status changes to 'closed'You can enter data or calculate statistics only while the inspection characteristic (or sample) status is set for processing.If you set a characteristic (sample) that has not yet been processed to 'processed', you have to close this characteristic (sample). You cannot reset the status of a processed characteristic (sample) back to 'not processed'.The usage decision for the inspection lot can only be made when the processing of all required characteristics is closed.
@Nullable public String getInspectionResultAttribute()
The system calculates statistics, such as the mean value, standard deviation and the number of fields only from valid single results.When you indicate that the result of a partial sample is invalid, the system reduces the summarized results data of the inspection characteristic by the results data of the invalid partial sample.
@Nullable public String getInspectionResultOrigin()
The keys for the origin of the results data are for information purposes only and have no controlling function.If a result is copied, for example from a certificate, this operation can be documented.
@Nullable public String getInspectionValuationResult()
For the valuation of the characteristic a distinction is made between the acceptance decision for the inspected units and the impact on similar future inspections (dynamic modification of samples).To display a list of all possible values for the valuation of the characteristic (or partial sample), select the list function. You valuate the characteristic (sample) using the 'Valuate' function.The sampling procedure that references a valuation mode defines how the valuation of an inspection characteristic (or partial sample) is to be carried out. The sampling procedure can be assigned to the inspection characteristics in the inspection plan.If you do not assign a sampling procedure to the inspection characteristic in the inspection plan, you have to valuate the inspection characteristic (or partial sample) manually.If the valuation of an inspection characteristic (or partial sample) is successful, the valuation is documented by means of a change to the record status. You can no longer enter data in the recording screen for the inspection characteristic (or partial sample) after the valuation.The valuation is unsuccessful if the predefined valuation procedure cannot reach a decision to accept or reject the characteristic (or partial sample).The most common reason for an unsuccessful valuation is that the inspection results needed for the valuation are either partially or completely missing.
@Nullable public Double getInspectionResultMeanValue()
If summarized results recording is defined for an inspection characteristic and the field is ready for input, enter the mean value of the valid measured values.For characteristics with single-value recording the system automatically determines the mean value after each entry.
@Nullable public String getInspectionResultHasMeanValue()
If this indicator is set, then the value of the corresponding numeric field is not initial.
@Nullable public Double getInspectionResultMaximumValue()
If summarized results recording is defined for an inspection characteristic and the field is ready for input, enter the maximum value of the valid measured values.For characteristics with single-value recording the system automatically determines the maximum value of the valid measured values that were confirmed, if youselect the function for calculating statistical momentsvaluate the characteristic (partial sample)
@Nullable public String getInspResultHasMaximumValue()
If this indicator is set, then the value of the corresponding numeric field is not initial.
@Nullable public Double getInspectionResultMinimumValue()
If summarized results recording is defined for an inspection characteristic and the field is ready for input, enter the minimum value of the valid measured values.For characteristics with single-value recording the system automatically determines the minimum value of the valid measured values that were confirmed, if youselect the function for calculating statistical momentsvaluate the characteristic (partial sample)
@Nullable public String getInspResultHasMinimumValue()
If this indicator is set, then the value of the corresponding numeric field is not initial.
@Nullable public String getInspectionResultOriginalValue()
@Nullable public Integer getInspResultValidValuesNumber()
If the field is ready for input, enter the inspected sample size.For each inspection plan characteristic you define the amount by which the inspected sample size in the 'Insp.ed' field can deviate from the to-be-inspected sample size in the 'Inspect' field. If a characteristic (partial sample ) is closed the system checks whether the required sample size is adhered to. The characteristic (partial sample) can only be closed if this is the case.For inspection characteristics, you can define conditions for adhering to the sample size. For example, you can define whether the inspection scope must be adhered to or whether it may be larger or smaller, etc.
@Nullable public String getInspectionResultText()
@Nullable public String getInspectionResultHasLongText()
@Nullable public String getCharacteristicAttributeCodeGrp()
@Nullable public String getCharacteristicAttributeCode()
The code can be uniquely identified only with the catalog type and code group.
@Nullable public String getInspRsltFreeDefinedTestEquip()
The number of the machine used to produce the partThe test equipment used for the inspectionYou can use the input help to search for and select an equipment master record or a production resources and tools master record. You can, however, also make a free entry.NotesThe display function in the field is only active when an equipment master record or a production resources and tools master record has been entered.The field supports uppercase and lowercase letters.When making an entry, no check is performed to see if the SAP object exists.The check whether an SAP object exists can be performed, for example, in the enhancements for the valuation or completion of a characteristic.
@Nullable public Integer getInspRsltBelowToleranceValsNmbr()
The system determines the number of nonconforming single values for the inspection characteristic or the partial sample from the number of valid single values outside the tolerance range.If the field is ready for input and the characteristic has a lower tolerance limit, you enter the number of measured values below the tolerance range. This number must not be greater than the number of valid single values.In the inspection plan you can define whether the characteristic is quantitative or not and whether it has tolerance limits.
@Nullable public Integer getInspRsltAboveToleranceValsNmbr()
The system determines the number of nonconforming single values for the inspection characteristic or the partial sample from the number of valid single values outside the tolerance range.If the field is ready for input and the characteristic has an upper tolerance limit, you enter the number of measured values above the tolerance range. This number must not be greater than the number of valid single values.In the inspection plan you can define whether the characteristic is quantitative or not and whether it has tolerance limits.
@Nullable public Integer getInspRsltNonconformingValsNmbr()
If the field is ready for input, enter the number of nonconforming sample units.The number of nonconforming sample units cannot be greater than the number of inspected test units that can be confirmed as the number of valid measured values.
@Nullable public Double getInspRsltAboveToleranceFraction()
The share is displayed in per cent. For example, 0.112 stands for a share of 11.2 per cent.The share of units for the characteristic or sample that is above the tolerance range is calculated if youselect the function for calculating the sharevaluate the characteristic (or the sample)close the characteristic (or the sample)This is only the case if the characteristic has an upper tolerance limit.The number of decimal places can be predefined at the plant level.For each characteristic with a tolerance range you can define in the inspection plan how the share calculation is to be carried out. The share calculation depends on whether, for example, measured values or the share of nonconforming units should be confirmed.
@Nullable public Double getInspRsltBelowToleranceFraction()
The share is displayed in per cent. For example, 0.112 stands for a share of 11.2 per cent.The share of units for the characteristic or sample that is below the tolerance range is calculated if youselect the function for calculating the sharevaluate the characteristic (or the sample)close the characteristic (or the sample)This is only the case if the characteristic has a lower tolerance limit.The number of decimal places can be predefined at the plant level.For each characteristic with a tolerance range you can define in the inspection plan how the share calculation is to be carried out. The share calculation depends on whether, for example, measured values or the share of nonconforming units should be confirmed.
@Nullable public Double getInspResultVariance()
For inspection characteristics with single-value recording the system determines the standard deviation of the confirmed and valid measured values if youselect the function for calculating statistical moments --OR--valuate the inspection characteristic (partial sample)
@Nullable public String getCharacteristicAttributeCatalog()
If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
@Nullable public String getInspectionResultCatalog2()
If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
@Nullable public String getInspectionResultCatalog3()
If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
@Nullable public String getInspectionResultCatalog4()
If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
@Nullable public String getInspectionResultCatalog5()
If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
@Nullable public String getInspectionResultCode2()
The code can be uniquely identified only with the catalog type and code group.
@Nullable public String getInspectionResultCode3()
The code can be uniquely identified only with the catalog type and code group.
@Nullable public String getInspectionResultCode4()
The code can be uniquely identified only with the catalog type and code group.
@Nullable public String getInspectionResultCode5()
The code can be uniquely identified only with the catalog type and code group.
@Nullable public String getInspectionResultCodeGroup2()
@Nullable public String getInspectionResultCodeGroup3()
@Nullable public String getInspectionResultCodeGroup4()
@Nullable public String getInspectionResultCodeGroup5()
@Nullable public String getCreatedByUser()
The system automatically enters the user name.
@Nullable public Calendar getCreationDate()
The system enters the current system date.
@Nullable public String getLastChangedByUser()
@Nullable public Calendar getLastChangeDate()
The system enters the current system date.
@Nullable public ErpConfigContext getErpConfigContext()
public void setInspectionLot(@Nullable String inspectionLot)
The inspection lot number is assigned by the system.
inspectionLot
- public void setInspPlanOperationInternalID(@Nullable String inspPlanOperationInternalID)
inspPlanOperationInternalID
- public void setInspectionCharacteristic(@Nullable String inspectionCharacteristic)
inspectionCharacteristic
- public void setInspector(@Nullable String inspector)
The system does not check the entries made.
inspector
- public void setInspectionResultStatus(@Nullable String inspectionResultStatus)
To display a list of all processing statuses that are possible for a characteristic or a sample, select the possible entries help.If you carry out one of the following functions, the processing status of the characteristic changes:enter data in the recording screen for the characteristic (sample):the processing status changes to 'processing'set for processing:the processing status changes to 'processing'valuate:the processing status changes to 'valuated'close:the processing status changes to 'closed'You can enter data or calculate statistics only while the inspection characteristic (or sample) status is set for processing.If you set a characteristic (sample) that has not yet been processed to 'processed', you have to close this characteristic (sample). You cannot reset the status of a processed characteristic (sample) back to 'not processed'.The usage decision for the inspection lot can only be made when the processing of all required characteristics is closed.
inspectionResultStatus
- public void setInspectionResultAttribute(@Nullable String inspectionResultAttribute)
The system calculates statistics, such as the mean value, standard deviation and the number of fields only from valid single results.When you indicate that the result of a partial sample is invalid, the system reduces the summarized results data of the inspection characteristic by the results data of the invalid partial sample.
inspectionResultAttribute
- public void setInspectionResultOrigin(@Nullable String inspectionResultOrigin)
The keys for the origin of the results data are for information purposes only and have no controlling function.If a result is copied, for example from a certificate, this operation can be documented.
inspectionResultOrigin
- public void setInspectionValuationResult(@Nullable String inspectionValuationResult)
For the valuation of the characteristic a distinction is made between the acceptance decision for the inspected units and the impact on similar future inspections (dynamic modification of samples).To display a list of all possible values for the valuation of the characteristic (or partial sample), select the list function. You valuate the characteristic (sample) using the 'Valuate' function.The sampling procedure that references a valuation mode defines how the valuation of an inspection characteristic (or partial sample) is to be carried out. The sampling procedure can be assigned to the inspection characteristics in the inspection plan.If you do not assign a sampling procedure to the inspection characteristic in the inspection plan, you have to valuate the inspection characteristic (or partial sample) manually.If the valuation of an inspection characteristic (or partial sample) is successful, the valuation is documented by means of a change to the record status. You can no longer enter data in the recording screen for the inspection characteristic (or partial sample) after the valuation.The valuation is unsuccessful if the predefined valuation procedure cannot reach a decision to accept or reject the characteristic (or partial sample).The most common reason for an unsuccessful valuation is that the inspection results needed for the valuation are either partially or completely missing.
inspectionValuationResult
- public void setInspectionResultMeanValue(@Nullable Double inspectionResultMeanValue)
If summarized results recording is defined for an inspection characteristic and the field is ready for input, enter the mean value of the valid measured values.For characteristics with single-value recording the system automatically determines the mean value after each entry.
inspectionResultMeanValue
- public void setInspectionResultHasMeanValue(@Nullable String inspectionResultHasMeanValue)
If this indicator is set, then the value of the corresponding numeric field is not initial.
inspectionResultHasMeanValue
- public void setInspectionResultMaximumValue(@Nullable Double inspectionResultMaximumValue)
If summarized results recording is defined for an inspection characteristic and the field is ready for input, enter the maximum value of the valid measured values.For characteristics with single-value recording the system automatically determines the maximum value of the valid measured values that were confirmed, if youselect the function for calculating statistical momentsvaluate the characteristic (partial sample)
inspectionResultMaximumValue
- public void setInspResultHasMaximumValue(@Nullable String inspResultHasMaximumValue)
If this indicator is set, then the value of the corresponding numeric field is not initial.
inspResultHasMaximumValue
- public void setInspectionResultMinimumValue(@Nullable Double inspectionResultMinimumValue)
If summarized results recording is defined for an inspection characteristic and the field is ready for input, enter the minimum value of the valid measured values.For characteristics with single-value recording the system automatically determines the minimum value of the valid measured values that were confirmed, if youselect the function for calculating statistical momentsvaluate the characteristic (partial sample)
inspectionResultMinimumValue
- public void setInspResultHasMinimumValue(@Nullable String inspResultHasMinimumValue)
If this indicator is set, then the value of the corresponding numeric field is not initial.
inspResultHasMinimumValue
- public void setInspectionResultOriginalValue(@Nullable String inspectionResultOriginalValue)
inspectionResultOriginalValue
- public void setInspResultValidValuesNumber(@Nullable Integer inspResultValidValuesNumber)
If the field is ready for input, enter the inspected sample size.For each inspection plan characteristic you define the amount by which the inspected sample size in the 'Insp.ed' field can deviate from the to-be-inspected sample size in the 'Inspect' field. If a characteristic (partial sample ) is closed the system checks whether the required sample size is adhered to. The characteristic (partial sample) can only be closed if this is the case.For inspection characteristics, you can define conditions for adhering to the sample size. For example, you can define whether the inspection scope must be adhered to or whether it may be larger or smaller, etc.
inspResultValidValuesNumber
- public void setInspectionResultText(@Nullable String inspectionResultText)
inspectionResultText
- public void setInspectionResultHasLongText(@Nullable String inspectionResultHasLongText)
inspectionResultHasLongText
- public void setCharacteristicAttributeCodeGrp(@Nullable String characteristicAttributeCodeGrp)
characteristicAttributeCodeGrp
- public void setCharacteristicAttributeCode(@Nullable String characteristicAttributeCode)
The code can be uniquely identified only with the catalog type and code group.
characteristicAttributeCode
- public void setInspRsltFreeDefinedTestEquip(@Nullable String inspRsltFreeDefinedTestEquip)
The number of the machine used to produce the partThe test equipment used for the inspectionYou can use the input help to search for and select an equipment master record or a production resources and tools master record. You can, however, also make a free entry.NotesThe display function in the field is only active when an equipment master record or a production resources and tools master record has been entered.The field supports uppercase and lowercase letters.When making an entry, no check is performed to see if the SAP object exists.The check whether an SAP object exists can be performed, for example, in the enhancements for the valuation or completion of a characteristic.
inspRsltFreeDefinedTestEquip
- public void setInspRsltBelowToleranceValsNmbr(@Nullable Integer inspRsltBelowToleranceValsNmbr)
The system determines the number of nonconforming single values for the inspection characteristic or the partial sample from the number of valid single values outside the tolerance range.If the field is ready for input and the characteristic has a lower tolerance limit, you enter the number of measured values below the tolerance range. This number must not be greater than the number of valid single values.In the inspection plan you can define whether the characteristic is quantitative or not and whether it has tolerance limits.
inspRsltBelowToleranceValsNmbr
- public void setInspRsltAboveToleranceValsNmbr(@Nullable Integer inspRsltAboveToleranceValsNmbr)
The system determines the number of nonconforming single values for the inspection characteristic or the partial sample from the number of valid single values outside the tolerance range.If the field is ready for input and the characteristic has an upper tolerance limit, you enter the number of measured values above the tolerance range. This number must not be greater than the number of valid single values.In the inspection plan you can define whether the characteristic is quantitative or not and whether it has tolerance limits.
inspRsltAboveToleranceValsNmbr
- public void setInspRsltNonconformingValsNmbr(@Nullable Integer inspRsltNonconformingValsNmbr)
If the field is ready for input, enter the number of nonconforming sample units.The number of nonconforming sample units cannot be greater than the number of inspected test units that can be confirmed as the number of valid measured values.
inspRsltNonconformingValsNmbr
- public void setInspRsltAboveToleranceFraction(@Nullable Double inspRsltAboveToleranceFraction)
The share is displayed in per cent. For example, 0.112 stands for a share of 11.2 per cent.The share of units for the characteristic or sample that is above the tolerance range is calculated if youselect the function for calculating the sharevaluate the characteristic (or the sample)close the characteristic (or the sample)This is only the case if the characteristic has an upper tolerance limit.The number of decimal places can be predefined at the plant level.For each characteristic with a tolerance range you can define in the inspection plan how the share calculation is to be carried out. The share calculation depends on whether, for example, measured values or the share of nonconforming units should be confirmed.
inspRsltAboveToleranceFraction
- public void setInspRsltBelowToleranceFraction(@Nullable Double inspRsltBelowToleranceFraction)
The share is displayed in per cent. For example, 0.112 stands for a share of 11.2 per cent.The share of units for the characteristic or sample that is below the tolerance range is calculated if youselect the function for calculating the sharevaluate the characteristic (or the sample)close the characteristic (or the sample)This is only the case if the characteristic has a lower tolerance limit.The number of decimal places can be predefined at the plant level.For each characteristic with a tolerance range you can define in the inspection plan how the share calculation is to be carried out. The share calculation depends on whether, for example, measured values or the share of nonconforming units should be confirmed.
inspRsltBelowToleranceFraction
- public void setInspResultVariance(@Nullable Double inspResultVariance)
For inspection characteristics with single-value recording the system determines the standard deviation of the confirmed and valid measured values if youselect the function for calculating statistical moments --OR--valuate the inspection characteristic (partial sample)
inspResultVariance
- public void setCharacteristicAttributeCatalog(@Nullable String characteristicAttributeCatalog)
If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
characteristicAttributeCatalog
- public void setInspectionResultCatalog2(@Nullable String inspectionResultCatalog2)
If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
inspectionResultCatalog2
- public void setInspectionResultCatalog3(@Nullable String inspectionResultCatalog3)
If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
inspectionResultCatalog3
- public void setInspectionResultCatalog4(@Nullable String inspectionResultCatalog4)
If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
inspectionResultCatalog4
- public void setInspectionResultCatalog5(@Nullable String inspectionResultCatalog5)
If you are processing a quantitative characteristic or a qualitative characteristic for which the characteristic attributes indicator is not set, you can assign up to 4 code groups or selected sets to describe the inspection characteristic or the inspection method.NOTEYou CANNOT assign selected sets from catalog type 1 to quantitative characteristics or to qualitative characteristics for which the characteristic attributes indicator is not set.
inspectionResultCatalog5
- public void setInspectionResultCode2(@Nullable String inspectionResultCode2)
The code can be uniquely identified only with the catalog type and code group.
inspectionResultCode2
- public void setInspectionResultCode3(@Nullable String inspectionResultCode3)
The code can be uniquely identified only with the catalog type and code group.
inspectionResultCode3
- public void setInspectionResultCode4(@Nullable String inspectionResultCode4)
The code can be uniquely identified only with the catalog type and code group.
inspectionResultCode4
- public void setInspectionResultCode5(@Nullable String inspectionResultCode5)
The code can be uniquely identified only with the catalog type and code group.
inspectionResultCode5
- public void setInspectionResultCodeGroup2(@Nullable String inspectionResultCodeGroup2)
inspectionResultCodeGroup2
- public void setInspectionResultCodeGroup3(@Nullable String inspectionResultCodeGroup3)
inspectionResultCodeGroup3
- public void setInspectionResultCodeGroup4(@Nullable String inspectionResultCodeGroup4)
inspectionResultCodeGroup4
- public void setInspectionResultCodeGroup5(@Nullable String inspectionResultCodeGroup5)
inspectionResultCodeGroup5
- public void setCreatedByUser(@Nullable String createdByUser)
The system automatically enters the user name.
createdByUser
- public void setCreationDate(@Nullable Calendar creationDate)
The system enters the current system date.
creationDate
- public void setLastChangedByUser(@Nullable String lastChangedByUser)
lastChangedByUser
- public void setLastChangeDate(@Nullable Calendar lastChangeDate)
The system enters the current system date.
lastChangeDate
- public void setErpConfigContext(@Nullable ErpConfigContext erpConfigContext)
erpConfigContext
- public String toString()
toString
in class VdmObject<InspectionResult>
public boolean equals(Object o)
equals
in class VdmObject<InspectionResult>
public int hashCode()
hashCode
in class VdmObject<InspectionResult>
Copyright © 2018 SAP SE. All rights reserved.