Restricting the View for BOM Explosion You can either display an entire BOM or a restricted-scope BOM. To determine the scope of a multi-level BOM explosion, set the
Limited explosion
indicator.
To determine the scope of the BOM explosion:
If you want to display the entire BOM, do
not
set the
Limited explosion
indicator.
If you want to restrict the scope, set the
Limited explosion
indicator.
If you do this:
Assemblies kept in stock are only displayed and not exploded.
Exceptions:
Assemblies that have special procurement key
50
defining them as
phantom assemblies
are always displayed and exploded. The explosion does not depend on the values of other attributes.
Assemblies that have special procurement key
52
defining them as
produced directly
are handled in the same way as phantom assemblies – displayed and exploded.
Items that are not kept in stock are displayed and exploded.
Note
If you do not set any other indicator in the
Restrict view
dataset, the system displays all the components found.
However, if you only want to display specific items, you can enter the item status indicators and BOM item field values.
You can either display all the items in the BOM you want to explode, or filter the BOM so that it only includes certain items. You can filter items according to item status indicators or by entering certain field values.
There are 2 steps to exploding a bill of material:
The system explodes the entire BOM – irrespective of the selection criteria entered. This happens in the background.
The system reads the selection criteria entered, such as the
Item relevant to engineering/design
indicator. This status indicator works as a filter. The explosion result that you see on the screen shows only the items that meet the selection criteria entered. For example, only the items that are relevant to engineering/design are displayed.
To filter items by item status indicators:
If you want to display
all
the items in the BOM, do not set any indicators in the
Restrict view
dataset.
If you only want to display only certain items in the BOM, set one of the following indicators:
Item relevant to engineering/design
Item relevant to production
Item relevant to plant maintenance
Bulk material
PM assembly
PM assemblies are not exploded down further in BOM reporting functions.
To select items by specific field values:
Item category
The system only displays items with the item category you enter.
Relevancy to costing
The system only displays items that are relevant (or not relevant) to costing.
Relevancy to sales
The system only displays items that are relevant (or not relevant) to sales and distribution.
Spare part indicator
The system only displays items that are allocated to a spare part group and that have a specific spare part indicator.
You define groups for spare parts in Customizing for
Bills of Material.
Spare part selection
Items that have any spare part indicator
If you want to display all spare parts, enter X.
If you want to display spare parts that are relevant to production, enter 1.
If you want to display spare parts that are not relevant to production, enter 2.
Material provision indicator
Items that have a specific material provision indicator.
You define groups for materials to be provided in Customizing for
Bills of Material.
Material provision selection
Items that have any material provision indicator
If you want to display all materials to be provided, enter X.
If you want to display materials that are provided by a customer, enter 1.
If you want to display materials that are provided by a vendor, enter 2.
Assembly
If you enter an assembly, the display is filtered so that you only see the data of the assembly.
Component
If you enter a component, the system displays a summarized BOM just for this component.