SUMRESALL Name |
SUMRESALL Load Profile of All Non-Interval Customers |
|---|---|
Class |
|
Additional information |
The remaining curve is determined by subtracting the total load shapes of the interval customers and the losses in the energy-feeding area (optional) from the energy-feeding curve. The total load shapes of the interval customers have already been aggregated for each settlement unit The settlement step provides the basis for determining the load profile of a supplier’s non-interval customer in the analytical procedure. The total load shapes of the interval customer must be determined for each settlement unit (settlement steps SUMINTSU or SUMINTSU01 ) before you call the settlement step. |
Parameter number/type |
01 - Importing |
Parameter description |
PrInpLoad – Energy feeding curve The measurement unit of the energy feeding curve must be the same as that of the result profile (prLoad02) |
Parameter number/type |
02 – Importing |
Parameter description |
PrLoadSup01 - Load shape of interval customers for each settlement unit |
Parameter number/type |
03 – Importing optional |
Parameter description |
PrLossSup – Losses for each settlement unit |
Parameter number/type |
04 – Importing optional |
Parameter description |
PrLossAdd – Other losses in the energy feeding area |
Parameter number/type |
01 - Exporting |
Parameter description |
PrLoad02 - Load shape of all non-interval customers |