Settlement Procedure

 

SAP provides the following pre-defined settlement procedures:

  • VV2_SYNTH: Synthetic Settlement Procedure According to German Associations' Agreement Regarding Electric Energy (Monthly)

  • VV2_SCHEDU: Schedule Management According to German Associations' Agreement Regarding Electric Energy (Daily)

  • EXTANALYT: Enhanced Analytical Settlement Procedure (Optimized)

  • FINSETTL: Determining Overtake and Undertake Amounts

Caution Caution

The following procedures are obsolete and have been replaced by the new optimized enhanced analytical procedure (EXTANALYT):

  • VV2_ANALYT: Analytical Settlement Procedure According to German Associations' Agreement Regarding Electric Energy (Monthly)

  • VV2_ANAEXT: Enhanced Analytical Settlement Procedure According to German Associations' Agreement Regarding Electric Energy (Monthly)

If you already use one of these procedures, you can continue using it. However, the disadvantage is that these procedures cannot be used to determine undertake and overtake amounts and they do not perform as well as the settlement procedure EXTANALYT.

End of the caution.

Note Note

Procedures EXTANALYT and VV2_SYNTH can be used as upstream settlement procedures for determining overtake and undertake amounts (FINSETTL).

See also: Settlement procedure FINSETTL

End of the note.

All the procedures can be configured as a workflow and a report.

For each procedure the following settlement parameters were defined:

  • Input parameters evaluated in the settlement procedure to calculate the results.

  • Output parameters updated as the results of the settlement run.

  • Interim results contain temporary results from interim calculations that are further processed in subsequent settlement steps.

  • All the input and output parameters (interim results are optional) must, together with the role defined for the settlement procedure, be allocated to an EDM profile. This occurs via the allocation to the point of delivery (see Automatic Determination of Parameters under Execute Settlement Step). The settlement procedure can then only be successfully completed if all the profiles for input parameters and results can be determined at runtime.

The following tables summarize the parameter definition of the predefined settlement procedures.

Synthetic Settlement Procedure According to German Associations' Agreement Regarding Electric Energy (VV2_SYNTH)

VV2_SYNTH

Parameter Type

Parameter Name

Category

Description

Input parameter

PrLossSup

Profile

Losses for each settlement unit

Output parameter

PrLoadSupAll

Profile

Total load shape for each settlement unit including sub-settlement units

Interim result

PrLoadSup01

Profile

Load shape of interval customers of the settlement unit

Interim result

PrLoadSup02

Profile

Load profile of non-interval customers of the settlement unit

Interim result

PrLoadSup

Profile

Total load shape in settlement unit

Schedule Management According to German Associations' Agreement Regarding Electric Energy (VV2_SCHEDU)

VV2_SCHEDU

Parameter Type

Parameter Name

Category

Description

Input parameter

PrLossSup

Profile

Losses for each settlement unit

Input parameter

PrLossGrid

Profile

Losses in utility grid

Output parameter

PrLoadSupAll

Profile

Total load shape for each settlement unit including sub-settlement units

Output parameter

PrLoadGridAll

Profile

Total load shape in grid including lower-level grids

Interim result

PrLoadSup01

Profile

Load shape of interval customers of the settlement unit

Interim result

PrLoadSup02

Profile

Load profile of non-interval customers of the settlement unit

Interim result

PrLoadSup

Profile

Total load shape in settlement unit

Interim result

PrLoadSupGrid01

Profile

Load shape for interval customers of the settlement unit in the grid

Interim result

PrLoadSupGrid02

Profile

Load profile of non-interval customers of the settlement unit in the grid

Interim result

PrLoadGrid

Profile

Total load shape in utility grid

Enhanced Analytical Settlement Procedure (EXTANALYT)

EXTANALYT

Parameter Type

Parameter Name

Category

Description

Input parameter

PrInpLoad

Profile

Energy feeding curve

Input parameter

PrLossAdd

Profile

Other losses in the energy feeding area

Input parameter

PrLoadSup

Profile

Losses for each settlement unit

Output parameter

PrLoadSupAll

Profile

Total load shape for each settlement unit including sub-settlement units

Interim result

PrLoadSup01

Profile

Load shape of interval customers of the settlement unit

Interim result

PrLoadSup02

Profile

Load profile of non-interval customers of the settlement unit

Interim result

PrLoadSup

Profile

Total load shape in settlement unit

Interim result

PrLoad02

Profile

Load profile of all non-interval customers

Interim result

PrFactGrp

Profile

Distribution factors for customer group

Interim result

PrFactSupGrp

Profile

Supplier factor for customer group

Interim result

PrLoadSupGrp01s

Profile

Load profile of non-interval customers of the customer group for each settlement unit (synthetic based on forecasted usage factors)

Determining Overtake and Undertake Amounts (FINSETTL)

FINSETTL

Parameter Type

Parameter Name

Category

Description

Input parameter

PrInpLoad

Profile

Energy feeding curve

Input parameter

PrLoadSupSettl

Profile

Settled total load shape in settlement unit

Input parameter

PrLossSup

Profile

Losses for each settlement unit

Input parameter

PrLossAdd

Profile

Other losses in the energy feeding area

Output parameter

PrDiffLoadSup

Profile

Overtake and undertake amount in settlement unit

Interim result

PrLoadSup

Profile

Total load shape in settlement unit