Settlement Procedure
SAP provides the following pre-defined settlement procedures:
VV2_SYNTH
: Synthetic Settlement Procedure According to German Associations' Agreement Regarding Electric Energy (Monthly)
VV2_SCHEDU
: Schedule Management According to German Associations' Agreement Regarding Electric Energy (Daily)
EXTANALYT
: Enhanced Analytical Settlement Procedure (Optimized)
FINSETTL
: Determining Overtake and Undertake Amounts
Caution
The following procedures are obsolete and have been replaced by the new optimized enhanced analytical procedure (EXTANALYT
):
VV2_ANALYT
: Analytical Settlement Procedure According to German Associations' Agreement Regarding Electric Energy (Monthly)
VV2_ANAEXT
: Enhanced Analytical Settlement Procedure According to German Associations' Agreement Regarding Electric Energy (Monthly)
If you already use one of these procedures, you can continue using it. However, the disadvantage is that these procedures cannot be used to determine undertake and overtake amounts and they do not perform as well as the settlement procedure EXTANALYT
.
Note
Procedures EXTANALYT
and VV2_SYNTH
can be used as upstream settlement procedures for determining overtake and undertake amounts (FINSETTL
).
See also: Settlement procedure FINSETTL
All the procedures can be configured as a workflow and a report.
For each procedure the following settlement parameters were defined:
Input parameters evaluated in the settlement procedure to calculate the results.
Output parameters updated as the results of the settlement run.
Interim results contain temporary results from interim calculations that are further processed in subsequent settlement steps.
All the input and output parameters (interim results are optional) must, together with the role defined for the settlement procedure, be allocated to an EDM profile. This occurs via the allocation to the point of delivery (see Automatic Determination of Parameters
under Execute Settlement Step). The settlement procedure can then only be successfully completed if all the profiles for input parameters and results can be determined at runtime.
The following tables summarize the parameter definition of the predefined settlement procedures.
Parameter Type | Parameter Name | Category | Description |
|---|---|---|---|
Input parameter |
| Profile | Losses for each settlement unit |
Output parameter |
| Profile | Total load shape for each settlement unit including sub-settlement units |
Interim result |
| Profile | Load shape of interval customers of the settlement unit |
Interim result |
| Profile | Load profile of non-interval customers of the settlement unit |
Interim result |
| Profile | Total load shape in settlement unit |
Parameter Type | Parameter Name | Category | Description |
|---|---|---|---|
Input parameter |
| Profile | Losses for each settlement unit |
Input parameter |
| Profile | Losses in utility grid |
Output parameter |
| Profile | Total load shape for each settlement unit including sub-settlement units |
Output parameter |
| Profile | Total load shape in grid including lower-level grids |
Interim result |
| Profile | Load shape of interval customers of the settlement unit |
Interim result |
| Profile | Load profile of non-interval customers of the settlement unit |
Interim result |
| Profile | Total load shape in settlement unit |
Interim result |
| Profile | Load shape for interval customers of the settlement unit in the grid |
Interim result |
| Profile | Load profile of non-interval customers of the settlement unit in the grid |
Interim result |
| Profile | Total load shape in utility grid |
Parameter Type | Parameter Name | Category | Description |
|---|---|---|---|
Input parameter |
| Profile | Energy feeding curve |
Input parameter |
| Profile | Other losses in the energy feeding area |
Input parameter |
| Profile | Losses for each settlement unit |
Output parameter |
| Profile | Total load shape for each settlement unit including sub-settlement units |
Interim result |
| Profile | Load shape of interval customers of the settlement unit |
Interim result |
| Profile | Load profile of non-interval customers of the settlement unit |
Interim result |
| Profile | Total load shape in settlement unit |
Interim result |
| Profile | Load profile of all non-interval customers |
Interim result |
| Profile | Distribution factors for customer group |
Interim result |
| Profile | Supplier factor for customer group |
Interim result |
| Profile | Load profile of non-interval customers of the customer group for each settlement unit (synthetic based on forecasted usage factors) |
Parameter Type | Parameter Name | Category | Description |
|---|---|---|---|
Input parameter |
| Profile | Energy feeding curve |
Input parameter |
| Profile | Settled total load shape in settlement unit |
Input parameter |
| Profile | Losses for each settlement unit |
Input parameter |
| Profile | Other losses in the energy feeding area |
Output parameter |
| Profile | Overtake and undertake amount in settlement unit |
Interim result |
| Profile | Total load shape in settlement unit |