public static final class ProductionRoutingOperation.ProductionRoutingOperationBuilder extends Object
@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder opCompAlloc(ProductionRoutingOpCompAlloc... value)
value
- The ProductionRoutingOpCompAllocs to build this ProductionRoutingOperation with.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder subOp(ProductionRoutingSubOperation... value)
value
- The ProductionRoutingSubOperations to build this ProductionRoutingOperation with.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder productionRoutingGroup(@Nullable String productionRoutingGroup)
Original property name from the Odata EDM: ProductionRoutingGroup
You can use groups, for instance, to identify two routings that have different production steps for one material.Enter the group to which you want to restrict the selection.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder productionRouting(@Nullable String productionRouting)
Original property name from the Odata EDM: ProductionRouting
In Production Planning and Control, for example, it serves to identify alternative production processes in task lists and is used to make a distinction between similar task lists.The group counter can be used to identify different lot-size ranges, for example.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder productionRoutingSequence(@Nullable String productionRoutingSequence)
Original property name from the Odata EDM: ProductionRoutingSequence
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder productionRoutingOpIntID(@Nullable String productionRoutingOpIntID)
Original property name from the Odata EDM: ProductionRoutingOpIntID
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder productionRoutingOpIntVersion(@Nullable String productionRoutingOpIntVersion)
Original property name from the Odata EDM: ProductionRoutingOpIntVersion
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder operation(@Nullable String operation)
Original property name from the Odata EDM: Operation
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder creationDate(@Nullable LocalDateTime creationDate)
Original property name from the Odata EDM: CreationDate
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder createdByUser(@Nullable String createdByUser)
Original property name from the Odata EDM: CreatedByUser
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder lastChangeDate(@Nullable LocalDateTime lastChangeDate)
Original property name from the Odata EDM: LastChangeDate
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder lastChangedByUser(@Nullable String lastChangedByUser)
Original property name from the Odata EDM: LastChangedByUser
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder changeNumber(@Nullable String changeNumber)
Original property name from the Odata EDM: ChangeNumber
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder validityStartDate(@Nullable LocalDateTime validityStartDate)
Original property name from the Odata EDM: ValidityStartDate
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder validityEndDate(@Nullable LocalDateTime validityEndDate)
Original property name from the Odata EDM: ValidityEndDate
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder operationText(@Nullable String operationText)
Original property name from the Odata EDM: OperationText
This text is copied into the first line of the long text for the operation or sub-operation.Character formats such as bold or italics are not supported in short texts. If you use special character formats in long texts, the system displays the corresponding control characters in the short text.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder longTextLanguageCode(@Nullable String longTextLanguageCode)
Original property name from the Odata EDM: LongTextLanguageCode
- the language in which texts are displayed,- the language in which you enter texts,- the language in which the system prints texts.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder plant(@Nullable String plant)
Original property name from the Odata EDM: Plant
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder operationControlProfile(@Nullable String operationControlProfile)
Original property name from the Odata EDM: OperationControlProfile
Which application component uses the controlkey for which objects is shown in the table below.QM PM PP PP-PI PSOperation/Activity x x x x xSub-Operation x x xPhase xSecondary Resource xActivity Element x
order (for example scheduling or costing).this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder operationStandardTextCode(@Nullable String operationStandardTextCode)
Original property name from the Odata EDM: OperationStandardTextCode
You can assign a standard text to an operation by entering the standard text key in the operation. By changing this text within the operation long text, you can then create an individual operation description.Standard texts can also be assigned to network activities.
or milling).this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder workCenterTypeCode(@Nullable String workCenterTypeCode)
Original property name from the Odata EDM: WorkCenterTypeCode
A - a work centerFH - a production resource/tool.The key is only used internally but it is displayed within matchcode selection on technical grounds. You do not have to make an entry.
indicators represent:this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder workCenterInternalID(@Nullable String workCenterInternalID)
Original property name from the Odata EDM: WorkCenterInternalID
When you work with infotype records, this field allows you to use the Fast entry feature. Fast entry enables you to create numerous infotype records without having to exit and re-enter the infotype window.To select the object that the infotype record should belong to, either:Enter the object's eight-digit codeUse the matchcode feature to search for the object
organizational unit, qualification or business event).this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder capacityCategoryCode(@Nullable String capacityCategoryCode)
Original property name from the Odata EDM: CapacityCategoryCode
You can allocate capacities of different capacity categories to a work center.
machine or labor capacity.this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder operationCostingRelevancyType(@Nullable String operationCostingRelevancyType)
Original property name from the Odata EDM: OperationCostingRelevancyType
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder numberOfTimeTickets(@Nullable BigDecimal numberOfTimeTickets)
Original property name from the Odata EDM: NumberOfTimeTickets
This entry is only taken into account if time tickets are to be printed according to the operation control key.The value from the work center is the default in the routing.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder numberOfConfirmationSlips(@Nullable String numberOfConfirmationSlips)
Original property name from the Odata EDM: NumberOfConfirmationSlips
The system prints confirmations if the control key for the operation or activity has been set.The value from the work center is the default in the routing.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder operationSetupType(@Nullable String operationSetupType)
Original property name from the Odata EDM: OperationSetupType
The value from the work center is the default in the routing.
crew).this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder operationSetupGroupCategory(@Nullable String operationSetupGroupCategory)
Original property name from the Odata EDM: OperationSetupGroupCategory
You can combine lathes with different setup group keys into a setup group category "Turning".
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder operationSetupGroup(@Nullable String operationSetupGroup)
Original property name from the Odata EDM: OperationSetupGroup
The setup group key is a criterion for sequence planning of orders in capacity leveling.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder operationReferenceQuantity(@Nullable BigDecimal operationReferenceQuantity)
Original property name from the Odata EDM: OperationReferenceQuantity
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder operationUnit(@Nullable String operationUnit)
Original property name from the Odata EDM: OperationUnit
Among other things, it is valid for:the base quantitythe minimum lot sizethe minimum send-ahead quantity when operations overlapThe operation unit of measure can deviate from the unit of measure for the task list if you change the numerator and denominator in the quotient for conversion.If the unit of measure in the header has already been maintained, this unit is used as a default value for the operation unit. You can change the unit of measure in the operation.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder opQtyToBaseQtyNmrtr(@Nullable BigDecimal opQtyToBaseQtyNmrtr)
Original property name from the Odata EDM: OpQtyToBaseQtyNmrtr
For example, if the routing unit of measure is "piece" and the operation unit of measure "kilogram" and for every 5 kgs there are 3 pieces, then the quotient is 3/5, because one kilogram is 3/5 of a piece.
operation unit of measure.this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder opQtyToBaseQtyDnmntr(@Nullable BigDecimal opQtyToBaseQtyDnmntr)
Original property name from the Odata EDM: OpQtyToBaseQtyDnmntr
For example, if the routing unit of measure is "piece" and the operation unit of measure "kilogram" and for every 5 kg there are 3 pieces, then the quotient is 3/5, because one kilogram is 3/5 of a piece.
operation unit of measure.this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardWorkQuantity1(@Nullable BigDecimal standardWorkQuantity1)
Original property name from the Odata EDM: StandardWorkQuantity1
The value of the standard value that you define in Customizing for the work center under Define formula parameters for work centersis used by the system just for checking formulas, unless the formula parameters have the origin 7.The system uses the standard value to conduct syntax checks for formulas. It is patrticularly advisable to maintain standard values for formula parameters that appear as divisors in formulas.For formula parameters with origin 7 (general formula constants) the value assignment is in Define formula parameters for work centers. Formula parameters with other origins acquire their values elsewhere, for instance, in the operation.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardWorkQuantityUnit1(@Nullable String standardWorkQuantityUnit1)
Original property name from the Odata EDM: StandardWorkQuantityUnit1
default value.this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder costCtrActivityType1(@Nullable String costCtrActivityType1)
Original property name from the Odata EDM: CostCtrActivityType1
Activity types describe the activity produced by a cost center and are measured in units of time or quantity.In activity type planning, control data determines whether the activity price for evaluation of the activity type is manually set or is derived iteratively through activity price calculation.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardWorkQuantity2(@Nullable BigDecimal standardWorkQuantity2)
Original property name from the Odata EDM: StandardWorkQuantity2
The value of the standard value that you define in Customizing for the work center under Define formula parameters for work centersis used by the system just for checking formulas, unless the formula parameters have the origin 7.The system uses the standard value to conduct syntax checks for formulas. It is patrticularly advisable to maintain standard values for formula parameters that appear as divisors in formulas.For formula parameters with origin 7 (general formula constants) the value assignment is in Define formula parameters for work centers. Formula parameters with other origins acquire their values elsewhere, for instance, in the operation.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardWorkQuantityUnit2(@Nullable String standardWorkQuantityUnit2)
Original property name from the Odata EDM: StandardWorkQuantityUnit2
default value.this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder costCtrActivityType2(@Nullable String costCtrActivityType2)
Original property name from the Odata EDM: CostCtrActivityType2
Activity types describe the activity produced by a cost center and are measured in units of time or quantity.In activity type planning, control data determines whether the activity price for evaluation of the activity type is manually set or is derived iteratively through activity price calculation.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardWorkQuantity3(@Nullable BigDecimal standardWorkQuantity3)
Original property name from the Odata EDM: StandardWorkQuantity3
The value of the standard value that you define in Customizing for the work center under Define formula parameters for work centersis used by the system just for checking formulas, unless the formula parameters have the origin 7.The system uses the standard value to conduct syntax checks for formulas. It is patrticularly advisable to maintain standard values for formula parameters that appear as divisors in formulas.For formula parameters with origin 7 (general formula constants) the value assignment is in Define formula parameters for work centers. Formula parameters with other origins acquire their values elsewhere, for instance, in the operation.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardWorkQuantityUnit3(@Nullable String standardWorkQuantityUnit3)
Original property name from the Odata EDM: StandardWorkQuantityUnit3
default value.this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder costCtrActivityType3(@Nullable String costCtrActivityType3)
Original property name from the Odata EDM: CostCtrActivityType3
Activity types describe the activity produced by a cost center and are measured in units of time or quantity.In activity type planning, control data determines whether the activity price for evaluation of the activity type is manually set or is derived iteratively through activity price calculation.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardWorkQuantity4(@Nullable BigDecimal standardWorkQuantity4)
Original property name from the Odata EDM: StandardWorkQuantity4
The value of the standard value that you define in Customizing for the work center under Define formula parameters for work centersis used by the system just for checking formulas, unless the formula parameters have the origin 7.The system uses the standard value to conduct syntax checks for formulas. It is patrticularly advisable to maintain standard values for formula parameters that appear as divisors in formulas.For formula parameters with origin 7 (general formula constants) the value assignment is in Define formula parameters for work centers. Formula parameters with other origins acquire their values elsewhere, for instance, in the operation.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardWorkQuantityUnit4(@Nullable String standardWorkQuantityUnit4)
Original property name from the Odata EDM: StandardWorkQuantityUnit4
default value.this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder costCtrActivityType4(@Nullable String costCtrActivityType4)
Original property name from the Odata EDM: CostCtrActivityType4
Activity types describe the activity produced by a cost center and are measured in units of time or quantity.In activity type planning, control data determines whether the activity price for evaluation of the activity type is manually set or is derived iteratively through activity price calculation.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardWorkQuantity5(@Nullable BigDecimal standardWorkQuantity5)
Original property name from the Odata EDM: StandardWorkQuantity5
The value of the standard value that you define in Customizing for the work center under Define formula parameters for work centersis used by the system just for checking formulas, unless the formula parameters have the origin 7.The system uses the standard value to conduct syntax checks for formulas. It is patrticularly advisable to maintain standard values for formula parameters that appear as divisors in formulas.For formula parameters with origin 7 (general formula constants) the value assignment is in Define formula parameters for work centers. Formula parameters with other origins acquire their values elsewhere, for instance, in the operation.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardWorkQuantityUnit5(@Nullable String standardWorkQuantityUnit5)
Original property name from the Odata EDM: StandardWorkQuantityUnit5
default value.this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder costCtrActivityType5(@Nullable String costCtrActivityType5)
Original property name from the Odata EDM: CostCtrActivityType5
Activity types describe the activity produced by a cost center and are measured in units of time or quantity.In activity type planning, control data determines whether the activity price for evaluation of the activity type is manually set or is derived iteratively through activity price calculation.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardWorkQuantity6(@Nullable BigDecimal standardWorkQuantity6)
Original property name from the Odata EDM: StandardWorkQuantity6
The value of the standard value that you define in Customizing for the work center under Define formula parameters for work centersis used by the system just for checking formulas, unless the formula parameters have the origin 7.The system uses the standard value to conduct syntax checks for formulas. It is patrticularly advisable to maintain standard values for formula parameters that appear as divisors in formulas.For formula parameters with origin 7 (general formula constants) the value assignment is in Define formula parameters for work centers. Formula parameters with other origins acquire their values elsewhere, for instance, in the operation.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardWorkQuantityUnit6(@Nullable String standardWorkQuantityUnit6)
Original property name from the Odata EDM: StandardWorkQuantityUnit6
default value.this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder costCtrActivityType6(@Nullable String costCtrActivityType6)
Original property name from the Odata EDM: CostCtrActivityType6
Activity types describe the activity produced by a cost center and are measured in units of time or quantity.In activity type planning, control data determines whether the activity price for evaluation of the activity type is manually set or is derived iteratively through activity price calculation.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder businessProcess(@Nullable String businessProcess)
Original property name from the Odata EDM: BusinessProcess
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder maximumWaitDuration(@Nullable BigDecimal maximumWaitDuration)
Original property name from the Odata EDM: MaximumWaitDuration
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder maximumWaitDurationUnit(@Nullable String maximumWaitDurationUnit)
Original property name from the Odata EDM: MaximumWaitDurationUnit
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder minimumWaitDuration(@Nullable BigDecimal minimumWaitDuration)
Original property name from the Odata EDM: MinimumWaitDuration
The minimum wait time must not exceed the maximum wait time.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder minimumWaitDurationUnit(@Nullable String minimumWaitDurationUnit)
Original property name from the Odata EDM: MinimumWaitDurationUnit
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardQueueDuration(@Nullable BigDecimal standardQueueDuration)
Original property name from the Odata EDM: StandardQueueDuration
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardQueueDurationUnit(@Nullable String standardQueueDurationUnit)
Original property name from the Odata EDM: StandardQueueDurationUnit
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder minimumQueueDuration(@Nullable BigDecimal minimumQueueDuration)
Original property name from the Odata EDM: MinimumQueueDuration
If the queue time is reduced in scheduling, the standard queue time can be reduced to this value.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder minimumQueueDurationUnit(@Nullable String minimumQueueDurationUnit)
Original property name from the Odata EDM: MinimumQueueDurationUnit
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardMoveDuration(@Nullable BigDecimal standardMoveDuration)
Original property name from the Odata EDM: StandardMoveDuration
(location group) to another.this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder standardMoveDurationUnit(@Nullable String standardMoveDurationUnit)
Original property name from the Odata EDM: StandardMoveDurationUnit
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder minimumMoveDuration(@Nullable BigDecimal minimumMoveDuration)
Original property name from the Odata EDM: MinimumMoveDuration
When the lead times are reduced in scheduling, the standard move time can be reduced to this time.
(location group) to another.this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder minimumMoveDurationUnit(@Nullable String minimumMoveDurationUnit)
Original property name from the Odata EDM: MinimumMoveDurationUnit
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder opIsExtlyProcdWithSubcontrg(@Nullable Boolean opIsExtlyProcdWithSubcontrg)
Original property name from the Odata EDM: OpIsExtlyProcdWithSubcontrg
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder inspectionLotType(@Nullable String inspectionLotType)
Original property name from the Odata EDM: InspectionLotType
an inspection lot origin.this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder purchasingInfoRecord(@Nullable String purchasingInfoRecord)
Original property name from the Odata EDM: PurchasingInfoRecord
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder purchasingOrganization(@Nullable String purchasingOrganization)
Original property name from the Odata EDM: PurchasingOrganization
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder purchaseContract(@Nullable String purchaseContract)
Original property name from the Odata EDM: PurchaseContract
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder purchaseContractItem(@Nullable String purchaseContractItem)
Original property name from the Odata EDM: PurchaseContractItem
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder purchasingInfoRecdAddlGrpgName(@Nullable String purchasingInfoRecdAddlGrpgName)
Original property name from the Odata EDM: PurchasingInfoRecdAddlGrpgName
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder plannedDeliveryDuration(@Nullable BigDecimal plannedDeliveryDuration)
Original property name from the Odata EDM: PlannedDeliveryDuration
If you have different vendors for a material, you must specify an average value. The same applies if you order the material from a fixed vendor that has varying delivery times.If you use the SAP Retail System, the planned delivery time can be suggested from the vendor sub-range in the vendor master record.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder materialGroup(@Nullable String materialGroup)
Original property name from the Odata EDM: MaterialGroup
You can use material groups to:Restrict the scope of analysesSearch specifically for material master records via search helps
them to a particular material group.this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder purchasingGroup(@Nullable String purchasingGroup)
Original property name from the Odata EDM: PurchasingGroup
The purchasing group is necessary for the creation of a purchase requisition, for example.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder supplier(@Nullable String supplier)
Original property name from the Odata EDM: Supplier
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder numberOfOperationPriceUnits(@Nullable BigDecimal numberOfOperationPriceUnits)
Original property name from the Odata EDM: NumberOfOperationPriceUnits
Invoices are created using price units and purchase order price units which constitute the basis for value postings.They can be stored in the purchasing info record.A material or commodity (for example, oil) can be ordered by the liter, but the supplier's invoice shows a price of 2 dollars per kilogram.You enter 10 l as the order quantity and order unit, but specify 2 dollars per kg as purchase order price and purchase order price unit.In addition, you enter the conversion factor "order unit -> purchase order price unit" (for example 2 l per 1 kg) in the "details" data of the purchase order item.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder costElement(@Nullable String costElement)
Original property name from the Odata EDM: CostElement
Cost elements are items in a chart of accounts that are relevant to cost and are used to enter all costs within the entire cost accounting system.Cost elements are a prerequisite for comprehensive reporting and detailed planning.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder opExternalProcessingPrice(@Nullable BigDecimal opExternalProcessingPrice)
Original property name from the Odata EDM: OpExternalProcessingPrice
The price is determined automatically by the system. Display the conditions to find out how the price was calculated.You can enter the following:The net price (that is the price including the supplier's discounts or surcharges).The gross price (that is the price excluding discounts or surcharges).You maintain the conditions for the item. The net price is then calculated by the system.During creation, you can only maintain the net price if you have not yet maintained the info record conditions. You must then maintain the price on the conditions screen.If the supplier's net price for the material has not been maintained in the info record, the net price of the last purchase order issued to the supplier is proposed when a new purchase order is created.
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder opExternalProcessingCurrency(@Nullable String opExternalProcessingCurrency)
Original property name from the Odata EDM: OpExternalProcessingCurrency
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder operationScrapPercent(@Nullable BigDecimal operationScrapPercent)
Original property name from the Odata EDM: OperationScrapPercent
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder changedDateTime(@Nullable ZonedDateTime changedDateTime)
Original property name from the Odata EDM: ChangedDateTime
this
.@Nonnull public ProductionRoutingOperation.ProductionRoutingOperationBuilder plainLongText(@Nullable String plainLongText)
Original property name from the Odata EDM: PlainLongText
this
.@Nonnull public ProductionRoutingOperation build()
Copyright © 2020 SAP SE. All rights reserved.