Activating or Deactivating Inspection TypesYou must have edited the QM-specific data in the Quality Management view of the material master.
You can activate an inspection type under the following conditions:
If it is not stock-relevant
If it is stock-relevant and at least one active stock-relevant inspection type exists
If it is the first stock-relevant inspection type and no inspection stock exists, or if you set the indicator
Activate despite insp. stock
When you deactivate the last inspection type relevant to stock, there must be no inspection stock for the material. To do this you must post the inspection lot quantities out of the inspection stock.
Choose
Choose
Activate insp. type
or
Deactivate insp. type
.
Select the materials, for which you want to activate or deactivate the inspection type. You can make the selection by using the plant, material, the material type and the material class.
Enter the required inspection type.
Edit the following indicators:
Indicator |
What You Should Know |
|
If you set this indicator, the system activates the inspection type in the materials, and adds it to those materials, to which the type was not previously assigned. If the inspection type did not exist, the system copies the parameters that are defined in Customizing as default values for the inspection type. |
|
If you set this indicator, inspection lots are created automatically, when you activate the first stock-relevant inspection type, to avoid stock inconsistencies between QM and MM. The inspection type for the inspection lots to be created is taken from Customizing . If you do not set this indicator, the inspection type for a material is only activated, if no stock inconsistencies will occur between QM and MM without the creation of additional inspection lots. |
|
If you set this indicator, the system immediately activates the inspection type for all selected materials, when the program is run. If you do not set this indicator, the system displays a list of materials. From this list, you can select the materials, for which you want to activate the inspection type. |
|
If you set this indicator, change documents are created for all changes that are made to the materials. You can display these change documents in the material master record. If you want to distribute inspection setup data via ALE, using change documents , you must set this indicator. This ensures that all changes to the inspection setup are distributed in other systems. |
Choose
Execute.
If you set the
Do not display material list
indicator, the chosen inspection type is activated immediately for all selected materials.
If you do not set the
Do not display material list
indicator, select the materials from the list, for which you want to activate or deactivate the inspection type and choose
Continue
.
Save the data.
Additional Functions in the Selection List for Mass Change
Function |
Pushbutton |
What You Should Know |
Display inspection setup |
|
You switch to the inspection setup in the Quality Management view of the material master. |
Display stock overview |
|
You switch to the stock overview for the chosen material. |