Processing Characteristics for Several Inspection LotsUsing this function, you can record the characteristic results for several inspection lots in a tabular form on a single screen.
This function provides the following processing options:
Displaying, recording, and changing characteristic results
Setting characteristics for processing
Branching to and returning from the display and processing transactions of the standard results recording function
Closing and saving the processed characteristics
Entering an inspection description (long text)
Calling up an error log
Calling up a control chart
Displaying the results history
Calling up an STI evaluation
The system displays the individual inspection lots with the recorded inspection results in columns in the table, sorted by the operations and their associated characteristics.
The entry fields for the characteristics that have not yet been valuated or closed are ready for input. If necessary, you can set the characteristics that have already been closed for processing by double-clicking them.
To save new results, choose
Close characteristics and save
. The system closes the characteristics that meet the requirements for being closed; the others are only saved. Your valuation is displayed in the table.