Define screen
selection for standard networks
In this step, you can make a field selection
for the screens in a standard network.
All screens for which field selection is
possible are grouped together in individual screen groups:
For each screen group, so-called "modifiable"
and "influencing" fields can be defined:
- For the modifiable fields, you use indicators
to determine how individual fields are displayed on the screen:
- Field is ready for input (default
setting)
- Field requires an entry (required
entry)
For example, if you
specify that the work center field requires an entry for list and detail
screens in network confirmation, then you must enter a work center every time
you make a confirmation.
- For the influencing fields, you use a value to
specify how the modifiable field is displayed on the screen. For example, you
can specify that the work center is a required entry for a particular order
type.
Notes
The settings of the field selection can be
transported and are retained during the release upgrades.
If, due to a change of an influencing field, a
modified field becomes mandatory, that is, it becomes a required entry, the
system does not check whether this field is filled in all existing
objects.
If you copy a standard network in a network,
the field selection of the standard network is ignored.
You can display the technical names of the
fields by choosing the menu options Edit -> Other
view.
Standard
Settings
No standard settings are available for field
selection.
The modifiable and influencing fields are
predefined for each screen group and cannot be extended.
Proceed as
follows to define a field selection.
You can define a field selection in several
ways
You maintain the indicators for
modifiable fields regardless of an influencing value
1. Position the
cursor on a screen group.
2. Click on
Modifiable.
All fields that can
be modified for this screen group are displayed on the screen.
3. Set the
indicators and save your entries.
You maintain an influencing value for
an influencing field and then the indicators for the modifiable
fields
1. Position the
cursor on a screen group.
2. Click on
Influencing.
All fields for which
you can maintain influencing values are displayed on the screen.
3. Double-click
on the influencing field for which you want to maintain a value.
All fields that can
be modified for the influencing value are displayed on the
screen.
4. Maintain a
value in field Influencing value and the corresponding indicators for
the modifiable fields.
5. Press
ENTER.
The entries are
transferred.
6. Maintain
further values for the influencing field or choose additional fields with
Influencing.
7. Save your
entries.
You maintain an indicator for a
modifiable field and determine the values of its influencing
fields
1. Position the
cursor on a screen group.
2. Click on
Modifiable.
All fields that can
be modified for this screen group are displayed on the screen.
3. Double-click
on the modifiable field for which you want to maintain influencing
values.
All influencing
fields are displayed on the screen.
4. Position the
cursor on an influencing field for which you want to store a value and choose
New values.
A dialog box is
displayed on the screen.
5. Maintain a
value and indicator for the influencing field and press
Continue.
The values are
transferred.
6. Save your
entries.
Activities
1. Determine
the screen group for which you want to modify fields.
2. Set the
indicators for the modifiable fields and the values for the influencing
fields.
3. Transport
your settings, if necessary. To do this, click on Field selection
-> Transport.