Define field
selection for confirmation
In this step you can select fields to appear
during network confirmation
All screens for which a field selection is
possible are grouped together in individual screen modification
groups:
- Parameters for confirmations
For each screen modification group, so-called
modifiable and influencing fields are defined:
- For the modifiable fields, you use indicators
to determine how the individual fields are shown on the screen:
- The field is ready for input (default
setting)
- The field requires an entry (required
entry)
- The field is display only
For example, if you
specify that the work center is a required entry forconfirmations of networks,
you must enter a work center in all confirmations.
- For the influencing fields, you determine via
a value how a modifiable field is shown on the screen. For example, that the
work center is a required entry for a certain order type.
Notes
You can transport the field selection settings
and the system retains them during release upgrades.
If you change an influencing field, you can
thereby change a modifiable field to a required entry (that is, mandatory),
the system will not check if entries have been made in this field in all
possible objects.
Standard
Settings
No default settings are available for field
selection.
The modifiable and influencing fields are
predefined for each screen modification group and cannot be added
to.
Proceed as
follows to define a field selection
There are several ways to define a field
selection
You maintain the indicators of the
modifiable fields, regardless of an influencing value
1. Position the
cursor on a screen modification group.
2. Choose the
function key Modifiable.
All fields that you
can modify for this screen modification group are displayed on the
screen.
3. Maintain the
indicators and save your entries.
For an influencing field, you maintain
an influencing value and then the indicators for the modifiable fields
1. Position the
cursor on a screen modification group.
2. Choose the
function key Influencing.
All fields for which
you can maintain influencing values are displayed on the screen.
3. Double click
to select the influencing field for which you want to maintain a
value.
All fields that you
can modify for the influencing value are displayed on the screen.
4. Maintain a
value in the field Influencing value and the corresponding indicators
for the modifiable fields.
5. Press
ENTER.
The entries are
copied.
6. Maintain
further values for the influencing field or select further fields using the
function key Influencing.
7. Save your
entries.
You maintain an indicator for a
modifiable field and determine the values of the influencing
fields
1. Position the
cursor on a screen modification group.
2. Choose the
function key Modifiable.
All fields that you
can modify for this screen modification group are displayed on the
screen.
3. Double click
to select a modifiable field for which you want to maintain influencing
values.
All influencing
fields are displayed on the screen.
4. Position the
cursor on an influencing field for which you would like to enter a value and
choose New values.
A dialog box is
displayed on the screen.
5. Maintain the
value and indicator for the influencing field and choose
Continue.
The values are
copied.
6. Save your
entries.
Activities
1. Determine
the screen modification group for which you want to modify
fields.
2. Maintain the
indicators for the modifiable fields and the values for the influencing
fields.
3. Transport
your settings, if necessary. To do this, choose Field selection
-> Transport.