Show TOC

Maintain Control Parameters for the Availability Check

In this step, you define the control for the availability check of capacities in networks. You determine which check is carried out by plant and network type.

If you want the system to check for available capacity automatically with the status created or when you release the network, you should make sure that the indicator No check is NOT set.

If you do not enter your own overall profile for the capacity availability check in the field CapAvailOverPro, the system uses overall profile SAPSFCG013. SAP has predefined the period week for the period profile in this overall profile.

Use the indicator release to specify, whether and how the network is to be release when there is not enough capacity.

Notes

The system automatically updates the parameters in the step Define checking control when you set them here.

Activities

1. Check whether the parameters for the capacity availability check have already been set.
2. Deselect the no check indicator.
3. Enter a different overall profile, if necessary.