icm/wp_mpi_available
The parameter
determines the minimum number of MPI buffers (granularity of the
Memory Pipes) read
by the network so that a rolled out context can be rolled back into a work
process (by the ICM).
To make sure that no work processes are occupied unnecessarily if the network connection is slow, you can use this parameter to ensure that the context only occupies one work process if data are also available.
Work area |
Internet Communication Manager |
Unit |
Integer value |
Standard value |
5 |
Dynamically changeable |
No |
Permitted values are between 1 and 50 MPI buffers.
Note the following documentation associated with this parameter:
Information about
communication between the ICM and the work process can be found under
Internet Communication
Manager (ICM).