Entering content frame

Function documentation Entering Measurement and Counter Readings Locate the document in its SAP Library structure

Use

You have five different options for entering measurement and counter readings in the R/3 System.

Overview of all Options for Entering Measurement and Counter Readings

This graphic is explained in the accompanying text

The PM-PCS Interface is an interface between the R/3 System and external systems, such as a Process Control System (PCS). Data from a process control system is data that arises during the monitoring, control, regulation, and optimization of a technical process. You can transfer this data to the R/3 System via the PM-PCS Interface. When transferring data, you can use a SCADA System (Supervisory Control and Data Acquisition System) which filters the data from the process control system and only transfers the data that is actually relevant to the R/3 System.

Features

Option for Entering Measurement and Counter Readings

Transfer into the R/3 System

For more information, see:

R/3 User Interface

No transfer, because data is created directly in the R/3 System.

Creating a Measurement Document

Internet Application Components

The data is transferred via the Internet into the R/3 System.

Structure link Entering Measurement and Counter Readings in the Internet

Barcode Reader

The data is transferred via the PM-PCS Interface into the R/3 System.

Entering Measurement and Counter Readings As Barcodes

Structure link PM-PCS Interface

Laptop

The data is transferred via the PM-PCS Interface into the R/3 System.

Structure link PM-PCS Interface

Process Control System with SCADA system (Supervisory Control And Data Acquisition system)

The data is transferred via the PM-PCS Interface into the R/3 System.

Structure link PM-PCS Interface

 

 

 

 

 