The following new functions are available for process message processing in process management:
Plant-Specific Sending of Process Messages in the Background
When you sent messages in the background in previous releases, the system used to send all messages in your client, irrespective of the plant in which they had been created. You can now use program RCOCB004 to define a background job that only sends messages of a specific plant. This enables you to process a smaller amount of data or take plant-specific settings into account.
Note
If you have activated the time zone function in your client, note the following when you define background jobs:
For more information, see the Implementation Guide (IMG) for Process Management.
Transferring of Order Numbers to Process Messages Headers
Until now, the order number was not contained in the process message header but only in the characteristics. For performance reasons, the system therefore used the other selection criteria in the message header to select messages in the message monitor until the maximum number of messages to be displayed was reached. Only then did the system perform a detailed selection and selected the messages with the order number that the user had entered from the messages found. Due to the maximum number specified, no messages or less messages than were actually available in some cases may therefore have been found for the process order. To avoid this and at the same time accelerate message selection, the order number is now also written to the order header as of this release, provided that a value is assigned to the standard characteristic for the order number in the process message.
For messages that were created before Release 4.6A, you can use program RCOCBX02 to transfer the order number to the message header. The program makes changes in the logon client only.
Depending on the number of process messages available in the logon client, the program runtime may be quite long. For this reason, we recommend scheduling the conversion as a background job. You can continue to work with your system as usual during the conversion.
If you want to use a plant-specific background job to send your process messages,
define the background job
in Customizing for Process Management. You may also need to deactivate the
existing background job for cross-plant sending in the job overview.