Improved CCMS monitor handling 
Description
The following improvements have been made to the Computing Center Management System monitors:
- System/Startup Monitor: All the functions of this monitor are now
available in each monitor view. That is, you can now branch to the
Alert details from the Startup view or start and stop instances from the System or Alert views.
A legend is also available now, which you can display or hide using menu
commands: Settings -> Legend -> Right/Left/Below/None.
You can also use Settings -> Infotext -> On/Off to display information.
If this Infotext is on, a text is displayed in the status line whenever
the mouse pointer is on a node. If you are in the System view, the Alert
status is displayed, for example "Red Alert". The instance status is
displayed (for example, "Operation mode unexpected") if you are in the Startup view.
- Menus and function keys: Only functions available to the monitors are
now displayed in the menus or as PF keys. SAP business graphic functions that cannot be used here are no longer displayed.